快速安装指南目录HP Performance Optimized Datacenter 40c G2 Site Preparation and Requirements Guide1Abstract1Notice2Contents3Overview5About this document5Safety and NEC compliance5Site assessment6Site preparation6Site safety and security6Fire detection and suppression6HP POD 40c G2 capacities7HP POD 40c G2 capacity limitations7Electrical power capacities (critical IT power)7Mechanical cooling capacities7Overall system capacities7Site requirements8Site pad8HP POD 40c G2 weight8Dimensions and clearances8Safety and clearance area10Future expansions11Grounding requirements11Utilities12Humidifier water supply12Drainage13Chilled water supply13Piping materials15Power infrastructure installation15Site electrical system15Electrical power system configuration15Transformers and switchboards16Supported facility connections17Environmental control system17Additional POD connections17Connection portals17Demarcation box18Fire box19Humidifier20HP POD 40c G2 security20Fire, safety, and security notifications20Environmental considerations22Environmental risks22Cold weather22Areas prone to lightning or power surges22Seismic activity22Site plan requirements and actions23Completing a site assessment23HP Site Preparation Drawing Package23Zoning and permit requirements23Project coordination23Site planning24HP POD 40c G2 installation24Installation equipment staging24HP POD 40c G2 lifting layout24HP POD 40c G2 lifting requirements25HP POD 40c G2 storage requirements25Additional structures25Appendix A: HP site assessment27HP POD 40c G2 site assessment checklist27Appendix B: Preparing for delivery31Pre-delivery tasks31Installation prerequisites31HP POD 40c G2 site readiness checklist31Appendix C: Regulatory compliance notices35HP POD 40c G2 regulatory compliance35Regulatory compliance identification numbers35Federal Communications Commission notice35Modifications35Cables36Canadian notice (Avis Canadien)36Glossary37Documentation feedback39Index40文件大小: 622.3 KB页数: 41Language: English打开用户手册
用户手册目录HP Performance Optimized Datacenter 40c G2 User Guide1Abstract1Notice2Contents3Overview6Before you begin6Operator safety6Component safety6Fire detection and suppression7Environmental considerations7Component identification8Structural component identification8Parts and part number identification8Life safety component identification9Electrical power component identification11Control cabinet component identification14HP POD 40c G2 racks14Life safety systems16Life safety overview16EPO system16ECS touchscreen and EPO indicators17EPO modes18EPO accidental activation18Battery backup during an EPO event18Fire protection system18Manual fire pulls19Fire alarm indicators19VESDA air sampling smoke detection system19(Optional) Fire suppression system20Fire system operator panel20Fire suppression sequence of operations21Emergency egress21Power, electrical, and controls22Site electrical system22Power safety22Grounding22Lightning protection23Capacities24HP POD 40c G2 capacity limitations24Electrical and mechanical cooling capacities24Power feeders24Electrical panels25Arc flash safety26Power distribution: Electrical busway system26Panel schedules27Wire color code27Control cabinet power components28Electrical busways28Drop boxes30Power configurations31Rack power31HP POD 40c G2 lighting31Environmental control system33Environmental control system overview33Using the ECS33Satellite control boxes34Sensors34Facility connections to ECS36Connecting to the ECS36Managing the ECS from the HP POD 40c G237Configuring the ECS37Logging in remotely to the ECS39Locating the ECS IP addresses40Password protection41Navigating the ECS interface41Overview screen43Status Overview screen45Basic System Configuration screen45Configuring the cold aisle temperature alarm parameters46Configuring the hot aisle temperature alarm parameters47Configuring the humidity alarm parameters47Configuring the differential pressure alarm parameters47Configuring the chilled water supply pressure alarm parameters48Configuring the chilled water supply pressure alarm parameters48Configuring the chilled water supply temperature alarm parameters48Configuring the chilled water return temperature alarm parameters49Setting the dimensions of the ECS49Advanced System Configuration screen49Calibrating the flowmeter51Calibrating the chilled water pressure sensors51Calibrating the differential pressure sensors51Enable/disable power management52Setting the IP address for each power meter52Setting the fan controls for each fan control zone52Setting the switchboard serial number52Setting the HP POD 40c G2 serial number52Controller Settings screen53ECS alarms54Safety and security alarms55Fire alarm sequence of operations55Cooling system56HP POD 40c G2 cooling system theory of operation56Water supply temperature56Water quality requirements and specifications57Cooling system components58Fans59Condensation management60Drains60Leak detection61IT networking and communications62Networking62Connection portals62Demarcation box63Fire box63Optional components65Fire protection system65Humidifier65Controlled access65Power up procedure66Standard HP POD 40c G2 power up procedure66Standard power up checklist66Standard power up procedure66Site electrical67Site chilled water67ECS and EPO67POD operation67Cold weather HP POD 40c G2 power up procedure67Cold weather power up checklist68Cold weather power up procedure68Site electrical68Site chilled water68ECS and EPO69POD heating procedure69POD operation69Power down procedure70Specifications71General HP POD 40c G2 specifications71Electrical specifications71Water specifications72Rack specifications72Thermal and air flow performance72Environmental specifications72Maintenance74Periodic maintenance74Sample HP POD 40c G2 maintenance schedule74Contacting HP75Before you contact HP75HP contact information75Regulatory compliance notices76HP POD 40c G2 regulatory compliance76Safety and NEC compliance76Regulatory compliance identification numbers77Federal Communications Commission notice77Modifications77Cables77Canadian notice (Avis Canadien)77Regulatory requirements for EXIT signs78Glossary79Documentation feedback82Index83文件大小: 1.8 MB页数: 84Language: English打开用户手册
服务手册目录HP Performance Optimized Datacenter 40c G2 Maintenance and Service Guide1Abstract1Notice2Contents3Illustrated parts catalog6Structural component identification6Parts and part number identification6Life safety component identification7Power feeders9Electrical panels10Cooling system component identification11HP POD 40c G2 racks11Replaceable spare parts12Removal and replacement procedures15Safety considerations15Operator safety15Fire detection and suppression15Air filter16Removing the air filter16Replacing the air filter17Busway drop box18Removing the busway drop box18Replacing the busway drop box19Differential pressure sensor20Removing the differential pressure sensor21Replacing the differential pressure sensor21Door position contact22Removing the door position contact22Replacing the door position contact22Drain pan sensor23Removing the drain pan sensor23Replacing the drain pan sensor24ECS touchscreen26Removing the ECS touchscreen26Replacing the ECS touchscreen27EPO button27Removing the EPO button28Replacing the EPO button29EPO LED indicators30Removing the EPO LED indicator30Replacing the EPO LED indicator31EPO thermister32Removing the EPO thermister32Replacing the EPO thermister32External chilled water flow actuator33Removing the external chilled water flow actuator33Replacing the external chilled water flow actuator35External chilled water flow valve35Removing the external chilled water flow valve36Replacing the external chilled water flow valve36External pressure gauge isolation valve37Removing the external pressure gauge isolation valve37Replacing the external pressure gauge isolation valve37Fan38Removing the fan38Replacing the fan39Fan bank40Removing the fan bank40Replacing the fan bank41Fire strobe light42Removing the fire strobe light42Replacing the fire strobe light43Humidifier43Removing the humidifier44Replacing the humidifier46Humidistat47Removing the humidistat47Replacing the humidistat48Humidity sensor50Removing the humidity sensor50Replacing the humidity sensor52LED light53Removing the LED light53Replacing the LED light54Temperature sensor (cold aisle)55Removing the cold aisle temperature sensor55Replacing the cold aisle temperature sensor56Temperature sensor (hot aisle)57Removing the hot aisle temperature sensor58Replacing the hot aisle temperature sensor59VESDA filter60Removing the VESDA filter61Replacing the VESDA filter61Periodic maintenance63Periodic maintenance overview63Cooling system maintenance schedule63Leak detection maintenance64Drains65ECS65Electrical65Fire alarm and suppression system67Generator (if applicable)67HP POD 40c G2 structure68Life safety68Security68Switchgear69Third-party components69UPS69Specifications70General HP POD 40c G2 specifications70Electrical specifications70Water specifications71Rack specifications71Thermal and air flow performance71Environmental specifications71Optional features specifications72Contacting HP73Before you contact HP73HP contact information73Regulatory compliance notices74HP POD 40c G2 regulatory compliance74Safety and NEC compliance74Regulatory compliance identification numbers75Federal Communications Commission notice75Modifications75Cables75Canadian notice (Avis Canadien)75Regulatory requirements for EXIT signs76Glossary77Documentation feedback79Index80文件大小: 2.4 MB页数: 82Language: English打开用户手册