用户手册目录Important Safety Instructions7Figure 1 Model number nomenclature81.0 Product Description91.1 General Product Information91.1.1 Product/System Description9Figure 2 Liebert XDP components91.1.2 Minimum Load9Table 1 Number of Liebert XD cooling modules required to achieve at least 48kW (163,800 BTU/H) load91.2 Equipment Inspection91.3 Equipment Handling101.3.1 Handling the Liebert XDP While it is on Skid and Packaged101.3.2 Unpacking the Liebert XDP11Figure 3 Unpacking the Liebert XDP111.3.3 Removing the Unit from the Skid Using a Forklift11Figure 4 Use a forklift to remove the Liebert XDP from the skid121.3.4 Removing the Unit from the Skid using Rigging12Figure 5 Removing the unit from the skid using rigging131.3.5 Moving the Liebert XDP Using Piano Jacks13Figure 6 Securing the Liebert XDP to piano jacks141.3.6 Removing the Unit from the Piano Jacks142.0 Installation152.1 Mechanical Considerations152.1.1 Positioning the Liebert XDP15Figure 7 Dimensions15Table 2 Liebert XDP dimensions15Figure 8 Piping access points16Table 3 Unit piping outlet connection sizes, inches, OD Cu162.2 Electrical Considerations162.2.1 Connecting High-Voltage Cables17Figure 9 Front view of Liebert XDP and electrical enclosure17Figure 10 Electrical enclosure knockout location for hazardous voltage wiring18Figure 11 High voltage connections—60Hz18Figure 12 High voltage connections—50Hz192.2.2 Extra Low Voltage (ELV) Connections19Figure 13 Electrical enclosure knockout locations for Extra Low Voltage19Figure 14 Connecting the remote temperature/humidity sensors202.2.3 DIP Switch and Jumper Settings for Remote Sensors21Figure 15 DIP switch and jumper settings21Figure 16 Unit-to-unit networking connections212.3 Field Connections—Optional for All Units22Figure 17 Liebert XDP extra low voltage field connections points222.4 Remote Sensor Installation—Proper Placement23Figure 18 Suggested remote sensor placement233.0 Piping243.1 European Union Fluorinated Greenhouse Gas Requirements243.2 Connection Sizes243.2.1 Recommended Pipe Size24Table 4 Supply, return pipe sizes for refrigerant loop243.3 Liebert XDP Interconnection with Liebert XD Cooling Modules25Figure 19 Liebert XD system diagram253.4 Piping Installation Methods253.4.1 Piping Installation—R-134a Pumped Circuit253.4.2 Piping Mains263.4.3 Bypass Flow Controller26Table 5 Bypass flow controllers for a Liebert XDP-based system26Figure 20 Bypass flow controller details, dimensions26Figure 21 Bypass flow controller arrangement27Figure 22 Bypass flow controller piping273.5 Piping Details—Shutoff/Isolation Valves27Figure 23 General piping details283.5.1 Evacuation and Leak Check—R-134a Pumped Circuit283.5.2 Insulation283.6 Filling the Pumped Circuit—R-134a29Table 6 System R-134a charge for a Liebert XDP with any model Liebert XDH/Liebert XDO/Liebert XDV/Liebert XDCF/Liebert XDR29Table 7 System refrigerant charge for the supply and return mains29Table 8 R-134a refrigerant charge for hard-piped connector lines to and from any model Liebert XDH/Liebert XDO/Liebert XDV/Liebert XDCF/Liebert XDR29Table 9 R-134a refrigerant charge for Flex Pipe connector lines to and from any model Liebert XDO/Liebert XDH/Liebert XDV/Liebert XDCF/Liebert XDR303.6.1 Calculating Refrigerant Charge—Example30Table 10 Calculating refrigerant charge—example30Table 11 Worksheet to calculate refrigerant charge303.7 Checklist for Proper Installation314.0 Liebert iCOM Control—Firmware Version XP1.00.010.STD324.1 Liebert iCOM Components and Functions32Figure 24 Liebert iCOM display components32Table 12 Keyboard icons and functions334.2 Display Lamp Indicators334.3 Navigating Through the Liebert iCOM Display34Figure 25 Liebert iCOM default home screen344.3.1 Accessing Menus and Settings34Viewing Data344.3.2 Cooling Module Overview35Figure 26 Cooling module overview, first 10 modules354.3.3 Entering the Password36Figure 27 Entering the password364.4 Changing Liebert iCOM’s Display Settings37Figure 28 Display setup screen374.5 Changing Operational Settings374.6 Graphical Data Record384.7 Liebert iCOM User Menu Icons and Legend38Figure 29 Liebert iCOM User Menu icons38Figure 30 Liebert XDP User Menu screen394.8 Liebert iCOM User Menu Screens40Figure 31 Setpoints screen40Spare Parts40Event Log40Figure 32 Set Alarms screen41Figure 33 Sensor Data screen, page 1 of 242Figure 34 Sensor Data screen, page 2 of 243Figure 35 Display Setup screen44Figure 36 Module Status screen, page 1 of 2045Figure 37 Liebert XDV Smart Module Status screen45Figure 38 Liebert XDH Smart Module Status screen—each bank shown separately46Figure 39 Liebert XDO Smart Module Status screen46Figure 40 Total Run Hours screen474.9 Liebert iCOM Service Menu Icons and Legend47Figure 41 Liebert iCOM Service Menu icons47Figure 42 Liebert XDP Service Menu screen484.10 Liebert iCOM Service Menu Screens48Figure 43 Setpoints screen48Figure 44 Maintenance—Basic Settings screen, page 1 of 750Figure 45 Maintenance—Pump 1 Settings screen, page 2 of 751Figure 46 Maintenance—Pump 2 Settings screen, page 3 of 752Figure 47 Maintenance screens, pages 4 through 752Figure 48 Diagnostics/Service Mode screen, page 1 of 653Figure 49 Diagnostics/Service Mode screen, page 2 of 653Figure 50 Diagnostics/Service Mode screen, page 3 of 654Figure 51 Diagnostics/Service Mode screen, page 4 of 654Figure 52 Diagnostics/Service Mode screen, page 5 of 655Figure 53 Diagnostics/Service Mode screen, page 6 of 655Figure 54 Set Alarms screen, page 1 of 756Figure 55 Set Alarms screen, page 2 of 757Figure 56 Set Alarms screen, page 3 of 758Figure 57 Set Alarms screen, page 4 of 759Figure 58 Set Alarms screens, pages 5 and 660Figure 59 Set Alarms screen, page 7 of 760Figure 60 Sensor Calibration/Setup screen, page 1 of 361Figure 61 Sensor Calibration/Setup screen, page 2 of 362Figure 62 Sensor Calibration/Setup screen, page 3 of 362Figure 63 System/Network Setup screen—System, page 1 of 263Figure 64 System/Network Setup screen—System, page 2 of 264Figure 65 System/Network Setup screen—Unit, page 1 of 265Figure 66 System/Network Setup screen—Unit, page 2 of 266Figure 67 Options Setup screen, page 1 of 267Figure 68 Options Setup screen, page 2 of 268Figure 69 Module Setup screen, page 1 of 2068Figure 70 Module Setup screen, page 1 of 20695.0 Start the Liebert XDP with Liebert iCOM705.1 Checklist for Liebert XDP Startup70Table 13 Liebert XDP pump light indicator—208V and 400V units705.2 Starting the Liebert XDP with Liebert iCOM Controller71Figure 71 System R-134a liquid level at 160kW load716.0 Alarm Descriptions and Solutions726.1 Alarm Descriptions726.2 Warning Descriptions746.3 System Shutdown Causes74Unit Is Off By Refrig Sens Fail74Unit Is Off By High CW Temp74Unit Is Off By Pump Short Cycle74Unit Is Off By Low Refrig Temp747.0 Troubleshooting75Table 14 Troubleshooting the Liebert XDP758.0 Maintenance778.1 Fluorinated Greenhouse Gas Requirements779.0 Specifications78Table 15 Liebert XDP160 specifications78文件大小: 2.8 MB页数: 80Language: English打开用户手册