用户手册目录1 About This User Guide211.1 Interpreting Typeface and Other Conventions211.2 Getting Additional Help231.3 Sending Feedback232 Avoiding Hazards242.1 Preventing Overexposure to RF Energy242.1.1 Calculations for Separation Distances and Power Compliance Margins242.1.1.1 Calculated Distances and Power Compliance Margins25Getting Started26For Your Safety263.2 Welcome273.2.1 About This Guide273.2.2 Who Should Use This Guide273.2.3 Contact Information283.2.4 Repair and Service283.3 Product Description293.3.1 The Outdoor Unit (ODU)313.3.2 PIDU Plus – PTP 600 Series Bridge323.3.3 Redundancy and Alternate Powering Configurations343.3.3.1 External DC Supply Only343.3.3.2 External DC Supply and AC Supply353.3.3.3 External DC Supply and Redundant AC Supply353.3.4 Remote LEDs and Recovery Switch363.3.5 Cables and connectors363.3.6 Surge Arrestor373.3.7 Mounting Brackets373.3.8 Configuration and Management383.4 Warranty384 Product Architecture395 General Considerations415.1 Spectrum Planning415.2 Region Codes425.3 Operational Restrictions435.3.1 Radar Avoidance435.3.2 RTTT Avoidance and Other Channel Use Restrictions445.4 5.4GHz Specific Frequency Planning Considerations455.4.1 Raster Considerations455.4.2 Transmit Power Reduction at the Band Edges455.4.3 5.8GHz Specific Frequency Planning Considerations465.4.4 Raster Considerations465.4.5 Transmit Power Reduction at the Band Edges465.5 Distance475.6 Networking Information485.7 Lightning Protection485.8 Electrical Requirements486 Site Planning496.1 Site Selection Criteria496.1.1 ODU Site Selection496.1.2 PTP 600 Series Bridge PIDU Plus Site Selection496.1.3 Path Loss Considerations506.1.4 Aggregate Ethernet throughput rate v maximum link loss517 Installation537.1 Preparation537.2 Installation Procedure537.3 Tools Required537.4 Installation Support547.5 Legal Disclaimer547.6 Mounting the ODUs547.7 Connecting Up567.7.1 Preparing The PIDU Plus To ODU Cable567.7.2 Making the Connections at the ODU587.7.3 Making the PTP 600 Series Bridge PIDU Plus Connection At The ODU597.7.4 Routing the Cable607.7.5 Fitting A Surge Arrestor607.7.6 Grounding the Installation617.7.7 Making the ODU Connection at the PTP 600 Series Bridge PIDU Plus617.7.8 Making the Network Connection at The PIDU Plus – PTP 600 Series Bridge627.7.9 Mounting the PTP 600 Series Bridge PIDU Plus637.7.10 Powering Up657.7.11 Aligning the PTP 600 Series Bridge ODUs668 Web Page Reference688.1 Home Page – PTP 600 Series Bridge708.1.1 Home Page Alarm Display718.2 Systems Status Page748.3 System Administration Pages798.3.1 System Configuration808.3.1.1 General Configuration Page818.3.1.2 LAN Configuration Page838.3.1.3 LAN Configuration Page – Use VLAN For Management Interfaces868.3.1.4 LAN Configuration Page – Manual Ethernet Configuration888.3.1.5 Save and Restore Configuration File898.3.1.6 Telecoms Configuration Page948.3.2 Statistics Page968.3.3 Detailed Counters Page998.3.4 Install Pages1018.3.4.1 Manually Configuring The Wireless Units1038.3.4.2 Internet Protocol Configuration1048.3.4.3 Telecoms Interface1068.3.4.4 Wireless Configuration1078.3.4.5 Disarm1138.3.5 Graphical Install1158.3.6 Software Upgrade1168.3.7 Spectrum Management1198.3.7.1 Wireless Channels1208.3.7.2 Spectrum Management Measurements1208.3.7.3 Measurement Analysis1208.3.7.4 The Spectrum Management Master / Slave Relationship1218.3.7.5 Spectrum Management Configuration1248.3.7.6 Barring Channels1258.3.7.7 Local and Peer Channel Spectrum Graphics1258.3.7.8 Active Channel History1278.3.7.9 Viewing Historic Spectrum Management Metrics1288.3.8 Spectrum Management (Fixed Frequency and WIMAX)1298.3.9 Spectrum Management Control - With Operational Restrictions1318.3.10 Remote Management Page1348.3.10.1 SNMP (Simple Network Management Protocol)1358.3.10.2 Supported Management Information Bases (MIBS)1358.3.10.3 SNMP Configuration1368.3.10.4 SMTP (Simple Mail Transport Protocol)1368.3.10.5 SNTP (Simple Network Time Protocol)1378.3.10.6 Setting the clock1378.3.11 Diagnostics1388.3.11.1 Diagnostic Plotter1398.3.11.2 Diagnostics Download1408.3.12 Change System Administration Password1418.3.13 License Key1428.3.14 Properties1448.3.15 Reboot1459 Recovery Mode1469.1 Upgrade Software Image1489.2 Reset IP & Ethernet Configuration1509.3 Erase Configuration1519.4 Reboot15410 Fault Finding15510.1 Hardware15510.1.1 Power15510.1.2 Ethernet15610.1.3 Checking your wiring15710.2 Radio15810.2.1 No Activity15810.2.2 Some Activity15911 Lightning Protection16011.1 Overview16011.1.1 Lightning Protection Zones16011.2 Detailed Installation16111.3 Testing Your Installation16811.3.1 Pre-Power Testing16811.3.2 Post-Power Testing16812 Wind Loading17012.1 General17012.2 Calculation of Lateral Force17012.3 Capabilities of the PTP 600 Series Bridges17112.4 Wind Speed Statistics17113 PTP 600 Series Bridge – Connectorized Model17313.1 Scope17313.2 Product Description17313.2.1 Hardware17313.2.2 Antenna Choices – 5.8 GHz17413.3 Software/Features17513.3.1 Status Page17513.3.2 Configuration Pages17613.3.3 Installation Pages17713.4 Deployment Considerations18113.5 Link Budget18113.6 Regulatory Issues18113.6.1 Antenna Choice (FCC Regions Only)18113.6.2 Cable Losses (FCC Regions Only)18213.7 Antennas for USA / Canada18213.8 Installation18513.8.1 Antenna Choice18513.8.2 Cables and Connectors18513.8.3 Tools18513.8.4 Miscellaneous supplies18613.8.5 Mounting the Connectorized 600 Series Bridge18613.8.6 Mounting the antennas18613.8.7 Alignment Process18713.8.8 Aligning Dual Polar Antennas18713.8.9 Aligning Separate Antennas18713.8.10 Completing the Installation18813.8.11 Antenna Cable Fixing18813.8.12 Antenna Connection Weatherproofing18813.9 Additional Lightning Protection19013.9.1 ODU Mounted Outdoors19013.9.2 ODU Mounted Indoors19114 E1/T1 Installation Guide19314.1 Preparing the PTP 600 Series Bridge E1/T1 Cable19314.2 Making the Connection at the ODU19514.3 Routing the Cable19814.4 Fitting a Surge Arrestor19814.5 Customer Cable Termination19814.6 Lightning Protection20014.6.1 Overview20014.6.2 Recommended Additional Components for E1/T1 Installation.20014.7 Surge Arrestor Wiring20314.8 Testing Your Installation20514.8.1 Pre-Power Testing20515 Data Rate Calculations20716 AES Encryption Upgrade21216.1 Configuring Link Encryption21316.1.1 License Keys21316.1.2 Encryption Mode and Key21516.2 Wireless Link Encryption FAQ21616.2.1 Encryption data entry fields are not available21616.2.2 Link fails to bridge packets after enabling link encryption21617 Legal and Regulatory Notices21717.1 Important Note on Modifications21717.2 National and Regional Regulatory Notices – 5.8 GHz variant21717.2.1 U.S. Federal Communication Commission (FCC) and Industry Canada (IC) Notification21717.2.2 European Union Notification21817.2.3 UK Notification21917.3 National and Regional Regulatory Notices – 5.4 GHz Variant22017.3.1 U.S. Federal Communication Commission (FCC) and Industry Canada (IC) Notification22017.3.2 European Union Notification22117.4 Exposure22317.5 Legal Notices22317.5.1 Software License Terms and Conditions22317.5.2 Hardware Warranty in U.S.22717.5.3 Limit of Liability22718 Glossary22819 FAQs22920 Index232Specifications23321.1 System Specifications23321.1.1 Wireless 5.4GHz Variant23321.1.2 Wireless 5.8GHz Variant23621.1.3 Management23921.1.4 Physical24021.1.5 Powering24021.1.6 Telecoms Interface24021.2 Safety Compliance24121.2.1 5.4 GHz Variant24121.2.2 5.8GHz Variant24121.3 EMC Emissions Compliance24221.3.1 5.4GHz Variant24221.3.2 5.8GHz Variant24221.4 EMC Immunity Compliance24321.5 Radio Certifications24421.5.1 5.4GHz Variant24421.5.2 5.8GHz Variant24421.6 Environmental Specifications24421.7 System Connections24521.7.1 PIDU Plus to ODU and ODU to Network Equipment Connections245文件大小: 3.1 MB页数: 246Language: English打开用户手册