用户手册目录FP-CTR-502 and cFP-CTR-502 Operating Instructions1Features1Installing the FP-CTR-5022Figure 1. Installing the FP-CTR-5022Installing the cFP-CTR-5022Figure 2. Installing the cFP-CTR-5023Wiring the [c]FP-CTR-5023Table 1. Terminal Assignments4Inputs5Figure 3. Wiring a Count-Input or Gate-Input Channel to a Sinking-Output Device6Outputs6Figure 4. Wiring an Output Channel to a Sourcing-Input Device7Figure 5. Wiring an Output to an Externally Powered Sourcing-Input Device7Configuring Count-Input Channels8Terminal Count8Channel Status8Count Source8Gate Source9Figure 6. Gate Source Set to External Gate Input9Read Reset Mode9Noise Rejection10Control10Configuring Gate-Input Channels10Configuring Output Channels10Output Source10Output Mode11Toggle, Reset Off11Figure 7. Output of a Channel Set to Toggle, Reset Off Mode11Toggle, Reset On11Figure 8. Output of a Channel Set to Toggle, Reset On Mode11On Pulse12Figure 9. Output of a Channel Set to On Pulse Mode12Off Pulse12Figure 10. Output of a Channel Set to Off Pulse Mode12Application Note: Generating a Continuous Pulse Train13Figure 11. Continuous Pulse Train13Step 1. Set Up the Prescaler Counter13Step 2. Set Up the Pulse Counter14Step 3. Configure the Pulse Train Output Channel15Status Indicators16Figure 12. Status Indicators16Upgrading the FieldPoint Firmware16Isolation and Safety Guidelines16Specifications18Input Characteristics18Output Characteristics18Physical Characteristics19Power Requirements19Isolation Voltage19Environmental19Shock and Vibration20Safety20Electromagnetic Compatibility20CE Compliance21Mechanical Dimensions21Figure 13. FP-CTR-502 Mechanical Dimensions21Where to Go for Support22文件大小: 447.4 KB页数: 22Language: English打开用户手册
用户手册目录FP-CTR-502 and cFP-CTR-502 Operating Instructions1Features1Installing the FP-CTR-5022Figure 1. Installing the FP-CTR-5022Installing the cFP-CTR-5022Figure 2. Installing the cFP-CTR-5023Wiring the [c]FP-CTR-5023Table 1. Terminal Assignments4Inputs5Figure 3. Wiring a Count-Input or Gate-Input Channel to a Sinking-Output Device6Outputs6Figure 4. Wiring an Output Channel to a Sourcing-Input Device7Figure 5. Wiring an Output to an Externally Powered Sourcing-Input Device7Configuring Count-Input Channels8Terminal Count8Channel Status8Count Source8Gate Source9Figure 6. Gate Source Set to External Gate Input9Read Reset Mode9Noise Rejection10Control10Configuring Gate-Input Channels10Configuring Output Channels10Output Source10Output Mode11Toggle, Reset Off11Figure 7. Output of a Channel Set to Toggle, Reset Off Mode11Toggle, Reset On11Figure 8. Output of a Channel Set to Toggle, Reset On Mode11On Pulse12Figure 9. Output of a Channel Set to On Pulse Mode12Off Pulse12Figure 10. Output of a Channel Set to Off Pulse Mode12Application Note: Generating a Continuous Pulse Train13Figure 11. Continuous Pulse Train13Step 1. Set Up the Prescaler Counter13Step 2. Set Up the Pulse Counter14Step 3. Configure the Pulse Train Output Channel15Status Indicators16Figure 12. Status Indicators16Upgrading the FieldPoint Firmware16Isolation and Safety Guidelines16Specifications18Input Characteristics18Output Characteristics18Physical Characteristics19Power Requirements19Isolation Voltage19Environmental19Shock and Vibration20Safety20Electromagnetic Compatibility20CE Compliance21Mechanical Dimensions21Figure 13. FP-CTR-502 Mechanical Dimensions21Where to Go for Support22文件大小: 447.4 KB页数: 22Language: English打开用户手册