用户手册目录Foreword7Conventions7Product recycling7Studer Innotec contact details8Your reseller’ contact details8Warnings and caution8Warnings and caution9Warranty9Limitation of responsability9Safety instructions9Acceptance of the software licence and updates9Introduction11Models concerned11Controls and indicators11SD card11Connection12Series connection12Dimensions13RCC-0213RCC-0313Quick Start Guide14Adjustment of the language14Adaptation to the source14Adaptation to the batterie15Activation of the function Smart-Boost16Basic displays17Activating and deactivating the combi Xtender18Adjustment of the RCC remote control19Adjustment of the language {5000}19Adjustment of date {5002) and time {5001}19Adjustment of the contrast {5006}19Adjustment of the back-lighting {5007}19Back-lighting always off {5008}19Duration of the back-lighting {5009}20Red back-lighting if the Xtender is OFF and if there is a fault {5026}20Inactivity period before returning to the standard display {5010}20Duration of display for quick messages {5011}20Acoustic alarm {5027}20User level {5012}20Drive the remote control to the user level basic {5019}20Backup and restoring {5013}20Backup of statistics {5014}20Backup of remote control configurations {5015}21Backup of Xtender configurations {5017}21Loading the remote control configurations {5016}21Loading the Xtender configurations {5018}21Loading a master file {5034}21Separator of the csv files {5032}21Information on the operating mode of the installation22Display of the parallel and three-phase systems23Event history24Alarm Low battery voltage24Stop Battery voltage too low24Stop High battery voltage24Message AC IN synchronisation in progress24Error Incorrect input frequency25Error Input voltage too high25Error Input voltage too low25Stop Inverter overvoltage25Stop Excessive battery voltage ripple25Error Voltage at AC Out26Stored events26Adjustment of the combi Xtender27Configuration on a system with several Xtenders27Pre-defined functions of the auxiliary relays27Basic configurations {1100}28Maximum current of the AC source (power sharing) {1107}28Locking {1123}28Authorised inverter {1124}28Authorised charger {1125}29Smart boost authorised {1126}29Authorised transfer {1128}29Automatic restart {1129}29Number of battery under-voltages allowed before final stop {1304} and29Leadtime to counting the battery under-voltages allowed before final stop {1404}29Number of critical battery under-voltages before final stop {1305} and30Restore default configurations {1395}30Battery cycle and charger {1137}30Charge current {1138}33Temperature correction coefficient {1139}33Battery maintenance voltage (floating) {1140}33Force passage to floating mode {1467}33New cycle {1141}33Force new cycle {1142}33New priority cycle on the absorption and equalization phases {1149}33Absorption phase {1451}34Authorised absorption {1155}34Absorption voltage {1156}34Duration of absorption {1157}34Completion of absorption released by the current {1158}34Current at end of absorption {1159}34Equalization phase {1452}34Start equalization {1162}34Authorised equalization {1163}34Equalization before absorption phase {1291}35Equalization current {1290}35Equalization voltage {1164}35Duration of equalization {1165}35Number of cycles prior to equalization {1166}35Equalization at set intervals {1284]35Weeks between equalizations {1285}35End of equalization activated by the current {1168}36End of equalization current {1169}36Inverter configurations {1186}36Standby level {1187}36Output voltage {1286}36Level of battery under-voltage at no load {1108}37Acoustic alarm of the battery under-voltage {1196}37Duration of the acoustic alarm {1469}37Combi configurations Inverter-Charger {1197}37Minimum AC In voltage to authorise the charging {1309}37Transfer AC-In for delayed transfer opening {1199}37Delay before passing to inverter {1198}38Immediate transfer AC-In voltage {1200}38Activate immediate detection of grid outage (UPS) {1435}38Solsafe presence {1438}38Delay before closing of the transfer relay {1528}38Configurations for auxiliary contacts 1 and 2 {1201} {1310}38Simple functions39Switching mode {1202} {1311}39Combination of events mode {1497} {1498}39Limit the time of activation {1512} {1513}40Maximum duration of activation {1514} {1515}40Temporal restrictions {1203} {1312}40Contacts activated by an event {1455} {1456}40Xtender OFF {1225} {1333}40Battery undervoltage alarm {1226} {1334}40Battery overvoltage {1227) {1335}40Inverter or smart boost overload {1228} {1336}41Overtemperature {1229} {1337}41No Overtemperature alarm {1520} {1521}41Active charger {1231} {1339}41Active inverter {1232} {1340}41Smart boost active {1233} {1341}41AC In present with fault {1234} {1342}41AC In present {1235} {1343}41Transfer relay drawn {1236} {1344}41AC Out present {1237} {1345}41Battery charging in bulk charge phase {1238} {1346}41Battery charging in absorption phase {1239} {1347}41Battery charging in equalization phase {1240} {1348}41Battery charging in floating phase {1242} {1350}41Contacts activated by the battery voltage {1245} {1353}41Dynamic compensation of the thresholds {1288} {1354}42Deactivate if the battery is in floating mode {1516} {1517}42Contacts activated by inverter power or smart boost {1257} {1366}42Contacts activated with set schedules {1269} {1378}42Extended functions {1489}43Generator startup {1490}43Generator startup {1491}43Duration of starter impulse {1492}43Number of startup attempts {1493}43Duration between the starter attempts {1494}43Multi Xtender {1282}433-phase integral mode {1283}43Information on the system44Remote controls44Xtender44Updates45Updating process45Compatibility45Application examples46général use : Inverter, Charger with grid46Use to increase the power on an existing installation47Annexes48Notes50文件大小: 1.1 MB页数: 51Language: English打开用户手册