用户手册目录INSTRUCTION MANUAL MODEL 200AH NITROGEN OXIDES ANALYZER1SAFETY MESSAGES3LIST OF TABLES101. HOW TO USE THIS MANUAL132. GETTING STARTED152.1. Unpacking152.2. Electrical and Pneumatic Connections152.3. Initial Operation213. SPECIFICATIONS, WARRANTY313.1. Specifications313.2. Warranty324. THE M200AH NOX ANALYZER334.1. Principle of Operation334.1.1. NOX Measurement334.1.2. Oxygen Measurement (Option)344.2. Operation Summary374.2.1. NOX Sensor Module, Reaction Cell, Detector374.2.2. Oxygen Sensor Module (Option)374.2.3. Pneumatic Sensor Board384.2.4. Computer Hardware and Software384.2.5. V/F Board394.2.6. Front Panel394.2.6.1. Keyboard394.2.6.2. Status LED's394.2.6.3. Power Switch404.2.7. Power Supply Module404.2.8. Pump, Valves, Pneumatic System404.2.9. Ozone Generator434.2.10. NO2 - NO Converter435. SOFTWARE FEATURES455.1. Index to Front Panel Menus455.1.1. Sample Menu505.1.2. Set-Up Menu515.2. Sample Mode555.2.1. Test Functions555.2.2. CAL, CALS, CALZ, Calibration Functions595.2.2.1. CAL, CALS, CALZ595.2.2.2. Gas To Cal595.2.2.3. Zero595.2.2.4. Span595.2.2.5. NO, NOX and O2 Cal Concentration605.2.2.6. Formula Values605.2.2.7. Automatic Converter Efficiency Compensation615.3. Set-Up Mode615.3.1. Configuration Information (CFG)615.3.2. Automatic Calibration (AutoCal)615.3.3. Data Acquisition System (DAS)625.3.3.1. Data Channels625.3.4. Range Menu645.3.4.1. Single Range (NOx Measurements)645.3.4.2. Auto Range and Remote Range (NOX Measurements)645.3.4.3. Independent Ranges (NOX Measurements)655.3.4.4. O2 Range655.3.4.5. Dilution Ratio655.3.4.6. Concentration Units665.3.4.7. Recorder Offset675.3.5. Password Enable675.3.6. Time of Day Clock675.3.7. Diagnostic Mode675.3.8. Communications Menu685.3.9. Variables Menu (VARS)685.4. M200AH Operating Modes695.4.1. NO/NOx/NO2 Switching Mode695.4.2. NOX Only Mode705.4.3. NO Only Mode705.5. 4-20 mA Current Loop715.6. Status Output715.7. RS-232 Interface725.7.1. Setting up the RS-232 Interface725.7.2. Command Summary755.7.3. TEST Commands and Messages795.7.4. WARNING Commands and Messages805.7.5. CALIBRATION Commands and Messages815.7.6. DIAGNOSTIC Commands and Messages825.7.7. DAS Commands and Messages835.7.8. VARIABLES Commands and Messages856. OPTIONAL HARDWARE AND SOFTWARE876.1. Rack Mount Options876.2. Zero/Span Valves Option886.2.1. Autocal - Setup Zero/Span Valves896.3. Oxygen Sensor Option906.4. Isolated 4-20 mA Current Loop Option916.5. Molybdenum Converter Option916.6. External Desiccant Canister Option916.7. Alternate Bypass Flow Orifice Option916.8. M501 External Converter Option917. CALIBRATION AND ZERO/SPAN CHECKS937.1. Manual NOX Zero/Span Check or Cal With Zero/Span Gas in the Sample Port957.2. Manual O2 Zero/Span Check or Cal With Zero/Span Gas in the Sample Port987.3. Manual Zero/Span Check with Zero/Span Valves Option997.4. Dynamic Zero/Span Calibration Using AutoCal1017.5. Use of Zero/Span Valves with Remote Contact Closure1027.6. NO Only Mode Calibration1037.7. NOX Only Mode Calibration1037.8. Calibration Requirements for AutoRange or Remote Range1037.9. Calibration Requirements for Independent Range1047.10. Calibration Quality1047.11. Converter Efficiency Compensation1057.12. Recommendations for CEM Applications1067.12.1. Calibration Gasses1067.12.2. Calibration Frequency1077.12.3. Converter Efficiency1078. MAINTENANCE1098.1. Maintenance Schedule1098.2. Replacing the Sample Particulate Filter1108.3. Replacing the Converter1128.4. Cleaning the Reaction Cell1148.5. Pneumatic Line Inspection1178.6. Leak Check Procedure1218.7. Light Leak Check Procedure1218.8. Prom Replacement Procedure1229. TROUBLESHOOTING AND ADJUSTMENTS1239.1. Operation Verification - Diagnostic Techniques1249.1.1. Fault Diagnosis with TEST Variables1249.1.2. Fault Diagnosis with WARNING Messages1309.1.3. Fault Diagnosis using DIAGNOSTIC Mode1329.1.3.1. Signal I/O Diagnostics1349.1.3.2. Electric Test1389.1.3.3. Optic Test1389.1.3.4. Ozone Gen Power1399.1.3.5. Analog Output Step Test1399.1.3.6. DAC Calibration1399.1.3.7. RS-232 Port Test1399.1.4. M200AH Internal Variables1399.1.5. Test Channel Analog Output1419.1.6. Factory Calibration Procedure1429.2. Performance Problems1469.2.1. AC Power Check1469.2.2. Flow Check1479.2.3. No Response to Sample Gas1479.2.4. Negative Output1489.2.5. Excessive Noise1489.2.6. Unstable Span1499.2.7. Unstable Zero1509.2.8. Inability to Span1509.2.9. Inability to Zero1509.2.10. Non-Linear Response1519.2.11. Slow Response1529.2.12. Analog Output Doesn't Agree With Display Concentration1529.3. Subsystem Troubleshooting and Adjustments1539.3.1. Computer, Display, Keyboard1539.3.1.1. Front Panel Display1539.3.1.2. Single Board Computer1539.3.1.3. Front Panel Keyboard1569.3.2. RS-232 Communications1569.3.2.1. RS-232 Port1589.3.3. Voltage/Frequency (V/F) Board1599.3.3.1. ADC/DAC Calibration Procedure1619.3.3.2. Changing Output Voltage Ranges1639.3.4. Status/Temp Board1659.3.4.1. Temperature Amplifier Section1659.3.4.2. Display Brownout1669.3.4.3. Status Output Lines, External Contact Closures1669.3.4.4. 4-20 mA Current Output1679.3.5. Power Supply Module1679.3.6. Ozone Generator1719.3.6.1. The PermaPure Drier1739.3.7. Flow/Pressure Sensor1759.3.8. NOX Sensor Module1809.3.8.1. PMT1809.3.8.2. Reaction Cell Temperature1809.3.8.3. Preamp Board1809.3.8.4. PMT Cooler1819.3.8.5. High Voltage P.S.1839.3.9. Z/S Valves1859.3.10. Pneumatic System1869.3.10.1. Leak Check1869.3.10.2. Pump186APPENDICES187APPENDIX A ELECTRICAL SCHEMATICS187APPENDIX B SPARE PARTS AND EXPENDABLES18902047 List, Spare Parts, M200AH19101713 Level 1 Spares Kit with Mini-HiCon Converter, M200AH1930171301 Level 1 Spares Kit with Moly Converter, M200AH19401714 Expendables Kit, M200AH195文件大小: 2.2 MB页数: 196Language: English打开用户手册