MAINTENANCE
MAINTENANCE 
INSTRUCTIONS
1)  Always turn off the gas valve before cleaning. 
For relighting, refer to lighting instructions. 
Keep the burner and control compartment 
clean by brushing and vacuuming at least 
once a year. When cleaning the logs, use a 
soft clean paint brush as the logs are fragile 
and easily damaged.
2)  Clean appliance and door with a damp 
cloth (never when unit is hot).  Never use 
an abrasive cleaner. The glass should be 
cleaned with a gas fi replace glass cleaner. 
The glass should be cleaned when it 
starts looking cloudy.
3)  The heater is fi nished in a heat resistant 
paint and should only be refi nished with heat 
resistant paint. Regency
®
 uses StoveBright 
Paint - Metallic Black #6309.
4)  Make a  periodic check of burner for proper 
position and condition. Visually check the 
fl ame of the burner periodically, making sure 
the fl ames are steady; not lifting or fl oating. 
If there is a problem, call a qualifi ed service 
person. 
5)  The appliance and venting system must be 
inspected before use, and at least annually, 
by a qualifi ed fi eld service person, to ensure 
that the fl ow of combustion and ventilation 
air is not obstructed.
Note:  Never operate the appliance without the 
glass properly secured in place.
6)  Do not use this appliance if any part has been 
under water. Immediately call a qualifi ed 
service technician to inspect the appliance 
and to replace nay part of the control system 
and any gas control which has been under 
water.
7)  Verify operation after servicing.
GENERAL VENT 
MAINTENANCE
Conduct an inspection of the venting system 
semi-annually. Recommended areas to inspect 
as follows:
1)  Check the Venting System for corrosion in 
areas that are exposed to the elements. 
These will appear as rust spots or streaks, 
and in extreme cases, holes. These compo-
nents should be replaced immediately.
2)  Remove the Cap, and shine a fl ashlight 
down the Vent. Remove any bird nests, 
or other foreign material.
3)  Check for evidences of excessive 
condensation, such as water droplets 
forming in the inner liner, and subsequently 
dripping out the joints, Continuous 
condensation can cause corrosion of 
caps, pipe, and fi ttings. It may be caused 
by having excessive lateral runs, too many 
elbows, and exterior portions of the system 
being exposed to cold weather.
4)  Inspect joints, to verify that no pipe 
sections or fi ttings have been disturbed, 
and consequently loosened. Also check 
mechanical supports such as Wall Straps, 
or plumbers' tape for rigidity.
GOLD-PLATED or 
BRASS LOUVERS/
TRIM
The 24 carat gold-plated or brass fi nish on the 
louvers and trim requires little maintenance, 
and need only be cleaned with a damp cloth. 
DO NOT use abrasive materials or chemical 
cleaners, as they may harm the fi nish and 
void the warranty.  Clean any fi ngerprints 
off before turning the unit on.
LOG REPLACEMENT
The unit should never be used with broken logs. 
Turn off the gas valve and allow the unit to cool 
before opening door and carefully remove the 
logs. (The pilot light generates enough heat to 
burn someone.) If for any reason a log should 
need replacement, you must use the proper 
replacement log. The position of these logs 
must be as shown in the diagrams under Log 
Installation.
Note:  Improper positioning of logs may 
create carbon build-up and will 
severely alter the unit's performance 
which is not covered under 
warranty.
NORMAL OPERATING 
SOUNDS OF 
GAS APPLIANCES
It is possible that you will hear some sounds 
from your gas appliance. This is perfectly normal 
due to the fact that there are various gauges 
and types of steel used within your appliance. 
Listed below are some examples. All are normal 
operating sounds 
and should not be considered 
as defects in your appliance.
Blower: 
Regency
®
 gas appliances use high tech blowers 
to push heated air farther into the room. It is not 
unusual for the fan to make a "whirring" sound 
when ON. This sound will increase or decrease 
in volume depending on the speed setting of 
your fan speed control.
Burner Tray: 
The burner tray is positioned directly under the 
burner tube(s) and logs and is made of a different 
gauge material from the rest of the fi rebox and 
body. Therefore, the varying thicknesses of steel 
will expand and contract at slightly different 
rates which can cause "ticking" and "cracking" 
sounds. You should also be aware that as there 
are temperature changes within the unit these 
sounds will likely re-occur. Again, this is normal 
for steel fi reboxes.
Blower Thermodisc: 
When this thermally activated switch turns ON 
it will create a small "clicking" sound. This is the 
switch contacts closing and is normal.
Pilot Flame: 
While the pilot fl ame is on it can make a very 
slight "whisper" sound.
Gas Control Valve: 
As the gas control valve turns ON and OFF, a 
dull clicking sound may be audible, this is normal 
operation of a gas regulator or valve.
Unit Body/Firebox: 
Different types and thicknesses of steel will 
expand and contract at different rates resulting 
in some "cracking" and "ticking" sounds will be 
heard throughout the cycling process.