REMOVING VALVE
1)  Shut off the gas supply.
2)  Remove the louvers (and bay door if it is 
on).
3)  Open the fl ush door and remove the door.
4)  Remove the logs.
5)  Remove the burner/grate assembly by 
removing the two Phillips head screws and 
then lift the burner assembly out.
Diagram 1: Remove the left and right screws 
and then lift out the burner/grate assembly.
6)  Remove the rear log stand by removing the 
2 screws.
7)  Disconnect the inlet gas line. See diagram 
2.
8)  Disconnect the 2 TP wires and the 2 TH 
wires from the valve.
9)  Remove the 10 Phillips head screws securing 
the valve tray assembly in place (diagram 2) 
and then lift the entire assembly out (diagram 
3).
Diagram 2: Rear Log Stand & Valve Tray Assembly
screws
Valve Tray Assembly
Rear Log Stand
screws
MAINTENANCE
INSTALLING VALVE
1)  Attach the valve to the valve bracket with 
the 4 (m5x8 metric) screws provided.
2)  Reconnect the "gas out" fl are fi tting with 
an 11/16" wrench.
3)  Reconnect the "gas out" fl are nut with a 
13/16" wrench.
4)  Install piezo ignitor push button assembly 
and reconnect wire.
5)  Reconnect the quick drop out thermocouple 
nut with a 9mm wrench.
6)  Reconnect the pilot tube nut with a 7/16" 
wrench.
7)  Scrape off the old gasket from the fl oor 
of the fi rebox and from the valve tray 
assembly.
8)  Install a new gasket and reinstall the valve 
tray assembly.
Note: Failure to install a new gasket 
may severely affect the appliance 
performance.
9)  Reinstall the 10 hold down screws.
10) Hook up the 2 TP and 2 TH wires to the 
appropriate connections on the valve.
11) Reinstall the front log stand.
12) Install Burner/grate assembly.
13) Hook up the gas line and check for gas 
leaks with a soap and water solution or a 
gas leak detector. (Do not use open fl ame 
for leak testing.)
14) Fire up the unit temporarily.
15) Check the manifold pressure.
16) Reinstall the logs and brick panels as 
needed.
17) Close the door and replace the louvers.
18) Fire up the unit again and check for proper 
fl ame appearance and glow on logs.
10) Undo the pilot tube from the valve with a 
 7/16" 
wrench.
11) Undo the quick drop out thermocouple nut 
on the valve with a 9mm (metric) wrench.
12) Remove the Piezo igniter wire and push 
button assembly.  
13) Undo the "gas out" fl are nut with a 13/16" 
wrench.
14) Undo the "gas out" fl are fi tting with an 11/16" 
wrench.
15) Remove the 4 Phillips head screws from 
the sides of the valve bracket and remove 
valve.
Hint: If you are using black pipe, ensure  that 
there is a union by the valve, otherwise removal 
will be almost impossible.
Diagram 3: Lift out Valve Tray Assembly