GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT
F.  STEP-BY-STEP INSTALLATION OF THE SYSTEM
WARNING!
Before starting, do the following:
1.
Wear gloves and safety glasses for protection.
2.
Keep hand tools in good contition. Sharpen cutting edges and make sure tool handles are secure.
3.
Always maintain the minimum air space required to the enclosure to prevent fire.
WARNING!
This appliance is equipped with a safety control system designed to protect against improper venting of com-
bustion products. Operation of this appliance when not connected to a properly installed and maintained venting
system, or tampering with a vent safety shut-off system can result in carbon monoxide (CO) poisoning and
possible death.
1. VENTING  REQUIREMENTS
A flue liner from the outlet of the draft hood to the roof
termination is required. This appliance is required to
be connected to a listed 4” diameter, stainless steel
or  aluminum  flexible  gas  vent  liner  with  a  top
termination. A 4” B-Vent or listed 4” rigid single wall
gas vent may also be used.
Before attempting to run your flue liner, you must make
sure that it will pass through the existing damper area;
this is best done with a flexible liner. In a zero clearance
(factory built) fireplace, the existing damper must be
removed or locked out of the way in the open position.
For  masonry  fireplaces,  if  the  damper  will  not  allow
the  passage  or  a  4”  flex,  do  not  proceed  without
consulting a local mason on how to remove or alter
the  damper  without  risk  of  structural  damage  or
leakage.
A minimum vertical venting height of 9 feet above the
base  of  the  appliance  must  be  maintined.  The
horizontal  run  must  not  exceed  50%  of  the  vertical
height. Maximum vertical venting height is 40’ above
the base of the appliance. The vent termination must
be  in  accordance  with  its  respective  listing  and
manufacturer’s  instructions.
Install 4” flue liner down through the chimney. When
using flexible liner, use caution around the offsets so
as not to rupture the liner. Measure up 16” from the
existing  fireplace  bottom  and  leave  hanging  in
fireplace.
2. GAS LINE INSTALLATION
A  gas  line  must  run  into  the  existing  woodburning
fireplace, for either a factory built or masonry fireplace.
If it is a factory built fireplace, the gas line should be
brought into the fireplace through the gas knockouts
provided.
Note: 
The appliance and its manual shutoff valve must
be  disconnected  from  the  gas  supply  piping  system
during any pressure testing of that system at test pres-
sures in excess of 1/2 psi (3.5 kPa). The appliance must
be isolated from the gas supply piping system by clos-
ing the manual shutoff valve during any pressure test-
ing  of  the  gas  supply  piping  system  at  test  pressures
equal to or less than 1/2 psi (3.5 kPa).
It  is  recommended  that  1/2”  inside  diameter  black
pipe be run into the fireplace through the right side. If
the  existing  fireplace  already  has  gas  run  to  it,  but
through the left side, it is recommended that the gas
be rerouted to the right side. See Figure 1.
Place an elbow at the end of the black pipe so that it
runs  perpendicular  to  the  face. A  1/3”  flare  adapter
(not  supplied)  is  necessary  to  connect  the  flex  line
(supplied) to the black pipe.
Check for leaks using a soap and water solution or a
leak detector.
Figure 1 - Gas Line Installation