GBI25 SERIES B-VENT GAS FIRED FIREPLACE INSERT
Seal with high temperature silicone at the point where
the  gas  line  enters  the  existing  fireplace  to  prevent
cold air infiltration.
This  fireplace  has  been  altered  to
accommodate  an  insert  and  should  be
inspected by a qualified service technician
prior to re-use as a conventional fireplace.
Note:
  The  above  label,  located  in  the  instruction
package, must be affixed to the existing fireplace prior
to installation of the GBi25 Gas Fired Fireplace Insert.
3. APPLIANCE INSTALLATION
a. Firebox Entry
To gain access to the draft hood, remove the two
screws located in the upper corners of the glass
frame. See Figure 2.
Figure 2 - Firebox Entry
Figure 3 - Glass Frame Removal
Rotate  glass  frame  forward  and  lift  out.  See
Figure 3.
Handle the glass frame with care to avoid striking
or  scratching  it  on  hard  objects  or  slamming  it
shut.
Remove the two screws on the baffle, as shown
in  Figure  4. To  remove  the  draft  hood,  unscrew
the  four  screws  located  around  the  exhaust
opening. See Figure 5. Slide the draft hood out of
the appliance and attach draft hood to flex liner in
appliance  with  a  minimum  of  three  sheet  metal
screws. A  4”  diameter  hose  clamp  may  also  be
used. See Figure 6.
The draft hood must be installed so as to be in
the  same  atmospheric  pressure  zone  as  the
combustion  air  inlet  to  the  appliance  and  shall
be located so that the relief opening is accessible
for checking vent operation.
Pack the area at the damper with noncombustible
insulation  to  prevent  cold  air  infiltration  into  the
fireplace cavity.
Figure 4 - Baffle Removal
Figure 5 - Draft Hood Removal
Figure 6 - Draft Hood Attachment
Label