Hearth & Home Technologies 2700-I Benutzerhandbuch

Seite von 28
2700-I  WOOD INSERT (ACT)
Page 12
September 1, 2008
7007-161H
OpTIONAL qUICK CONNECT COLLAR
OUTSIDE AIR INSTALLATION
The Outside Air Cover Boxes must be installed 
on both panel legs FIRST before installing the 
panels on the insert.  The boxes are included 
with the panel and Trim Kit Assembly.
NOTE:  The Factory-Built Fireplace must meet (UM) 84-
HUD requirements for outside combustion air supply to 
the fireplace fire chamber.
1.  Slide the Outside Air Cover Box over the louvers in 
the panel leg and wedge it between the panel leg and 
flange.  Secure with screw provided.
2.  Repeat for other side.
Chimney Ring Bolts
Grap handle and pull 
venting into firebox
Turn clockwise to lock
Line up slot 
with chimney 
ring bolt
Secure venting 
to collar
I
f you would like to use the Quick Connect Collar for easy 
flue installation and removal, follow the directions below.
1.  Attach venting to Quick Connect Collar.  Secure with 2 
screws.
2.  Remove baffle and ceramic blanket. 
See page 20.  
.  Partially  insert  chimney  ring  bolts  (1/4-20)  supplied  in 
component pack.
4.  Slide appliance into place.
5.  From inside the unit, reach through chimney ring hole, 
grab the horizontal bar handle pulling venting to the unit.  
Line up the slots in Quick Connect Collar with the bolts.
6.  Rotate  Quick  Connect  Collar  clockwise  and  tighten 
bolts.
7.  Re-install  baffle  and  ceramic  blanket  making  sure  they 
are fully pushed back into position.
Outside Air Inlet
Outside Air 
Cover Box
Back of 
Panel
Figure 12.1
Figure 12.2
Figure 12.3
WARNING
Do not draw outside combustion air from:
•  Wall, floor or ceiling cavity
•  Enclosed space such as an attic or garage
•  Close proximity to exhaust vents or chimneys.
Fumes or odor may result
Fire Risk.
Asphyxiation Risk.
Asphyxiation Risk.
Outside air inlet must be located to prevent blockage 
from:
•  Leaves, snow, ice or other debris
Blockage may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive 
individuals
WARNING
Asphyxiation Risk.
Length of outside air supply duct shall NOT exceed 
the length of the vertical height of the exhaust flue.
•  Fire will not burn properly
  Smoke spillage occurs when door is opened due 
to air starvation
WARNING