Honeywell THM5421C1008 Benutzerhandbuch

Seite von 40
VISIONPRO
®
 IAQ TOTAL HOME COMFORT SYSTEM
19
68-0287—1
Installer System Tests
When VisionPRO® IAQ is used in a zoning system you must exit the installer test on one thermostat before entering the installer 
test on another thermostat.
OPERATION
Thermostat Keys
Thermostat Display
Table 4. Installer System Test.
System Test Number
Test Type
ISU Value
System Status Number and Description
Test 1
Installer Test Cool
0
1
2
Off
Cool Stage 1
Cool Stages 1 & 2
Test 2
Installer Test Fan
0
1
Off
Fan On
Test 3
Installer Test Heat
0
1
2
3
4
Off
Heat Stage 1
Heat Stages 1, 2
Heat Stages 1,2,3
Heat Stages 1,2,3,4
Test 4
Emergency Heat Test
0
1
2
Off
AUX Heat Stage 1
AUX Heat Stages 1 and 2
Test 5
Installer Test Humidifier
0
1
Off
Humidifier On
Test 6
Installer Test Dehumidifier
0
1
Off
Dehumidifier On
Test 7
Installer Test Ventilator
0
1
Off
Ventilator On
Err
Diagnostic Recall
00-99
See “Communication Error Codes” on page 34
Press the Next button to go to the beginning of the Installer Setup or press the Done button to exit the Installer System Test.
SCHED
HOLD
CLOCK SCREEN
MORE
TUE
AM
FAN
AUTO
SYSTEM
HEAT
COOL
Following
Schedule
Inside
Set To
M23500
FAN
SELECTS
ON/AUTO/CIRC
SYSTEM
SELECTS EM. 
HEAT/HEAT/OFF/COOL
UP ARROW
RAISES 
TEMPERATURE
SETTING
DOWN ARROW
LOWERS TEMPERATURE
SETTING
SCHED
ENTERS
SCHEDULING
MODE
MORE
SHOWS ADDITIONAL
ACCESSORY AND 
MAINTENANCE 
OPTIONS
SCREEN
LOCKS OUT THE
SCREEN TO ALLOW 
FOR CLEANING
CLOCK
SETS THE
TIME
FORWARD
OR BACK
HOLD
SETS A PERMANENT
HOLD AND ACTIVITIES
VACATION HOLD
Humidity
SCHED
HOLD
CLOCK SCREEN
MORE
TU
A
M
FAN
AUTO
SYSTEM
EM HEAT
HEAT
OFF
COOL
Following
Schedule
Inside
Set To
M23501
FAN
SHOWS FAN
SETTING
TUE
SHOWS CURRENT DAY
OF THE WEEK
SYSTEM
SHOWS
CURRENT
SYSTEM
POSITION
TIME
DISPLAY CURRENT
TIME OF DAY, HOLD
TIME REMAINING OR
NUMBER OF VACATION
DAYS REMAINING
INSIDE TEMPERATURE
SHOWS THE CURRENT INSIDE 
TEMPERATURE
SET TO 
TEMPERATURE
SHOWS THE 
CURRENT SET 
TEMPERATURE
FOLLOWING 
SCHEDULE
SHOWS THE 
THERMOSTAT IS
FOLLOWING THE 
PROGRAMMED
SCHEDULE
Humidity