System
The System key selections vary based on your heating and/or 
cooling system type.
Heat — Thermostat controls the heating system.
Off — Both heating and cooling systems are off.
Cool — Thermostat controls the cooling system.
Auto — Thermostat automatically changes between heating 
and cooling operation, depending on indoor temperature.
Em. Heat — Emergency heat cycles to maintain temperature. 
Compressor is locked out and auxiliary heat turns on as 
needed.
Fan
The Fan key selections vary based on the heating and/or 
cooling system type.
On — Fan runs continuously. Use this setting for improved air 
circulation or for more efficient central air cleaning.
Auto — fan follows the fan program schedule.
Circ — fan runs randomly approximately 35% of the time. Use 
this setting for improved air circulation or for more efficient 
central air cleaning when you do not want the fan running 
continuously.
Control Humidification Level
The VisionPRO
®
 IAQ Touchscreen Thermostat reads the 
inside humidity level and allows for a humidification setting with 
or without frost protection. Humidification will only take place 
when the thermostat is in Heat mode or in Auto mode when the 
previous call was a call for heating.
WITH FROST PROTECTION
Controlling humidification with frost protection requires an 
outdoor temperature sensor. The Frost Index (scale 1–10) will 
limit the amount of humidity added to the air based on outdoor 
temperature, with 1=most dry and 10=most humid. This 
prevents frost from accumulating on windows.
WITHOUT FROST PROTECTION
The frost setpoint is not displayed, but a humidity setpoint can 
still be set.
1. Press the More key until the inside humidity level set-
point is shown.
2. Use Up and Down arrow keys, located to the right of the 
humidity setpoint, to set desired humidity level.
3. Press Done key.
Control Dehumidification Level
The VisionPRO
®
 IAQ Touchscreen Thermostat reads the 
inside humidity level and allows for a dehumidification setting, 
and can be set to dehumidify using the air conditioner or a 
whole house dehumidifier.
With Air Conditioner
The set range for dehumidification is 40 to 80%, and can be set 
in 5% increments. The thermostat must be in Cool mode or 
Auto mode when the previous call was a call for cooling.
Dehumidifying in this manner runs the air conditioner longer 
than simply cooling the house would require, and can be set to 
run 1, 2, or 3°F below the temperature setpoint. This feature is 
called Dehumidification Droop Control.
NOTE: You must use this setting if:
No powered, whole house dehumidifier is present, 
and
The system uses the air conditioner as the
dehumidifier.