Lucent Technologies Release 6 Benutzerhandbuch
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Test the System
Page 4-11
Test Expansion Interface Exchange for Each EPN
4
Test Expansion Interface Exchange for
Each EPN
Each EPN
Critical reliability only.
1. Verify the screen displays:
Command:
2. Enter status cabinet < 1-44> and press
Enter
. This displays the standby
expansion link (before changes are made). See
Screen 4-9
.
Screen 4-9.
Example of System Status Before Expansion Link is Set
3. Type set expansion-link xxxx
(where xxxx is the either 1 of the cabinet,
carrier, and port locations of the standby expansion link).
4. Verify the screen displays:
Command successfully completed
Command:
5. Enter status cabinet < 1-44> and press
Enter
. See
Screen 4-10
.
Screen 4-10.
Example of System Status after Expansion Link is Set
status system all-cabinets
SYSTEM STATUS CABINET 1
SYSTEM STATUS CABINET 1
EMERGENCY SELECT SERVICE CABINET
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A unavail 01A01-02A01 in standby MCC
1B auto-on 01B01-02B02 in active
-
-
Command successfully completed
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A unavail 01A01-02A01 in standby MCC
1B auto-on 01B01-02B02 in active
-
-
Command successfully completed
Command:
status system all-cabinets
SYSTEM STATUS CABINET 1
SYSTEM STATUS CABINET 1
EMERGENCY SELECT SERVICE CABINET
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A auto-on 01A01-02A01 in active MCC
1B auto-on 01B01-02B02 in standby
TRANSFER SWITCH EXP-LINK STATE MODE TYPE
1A auto-on 01A01-02A01 in active MCC
1B auto-on 01B01-02B02 in standby