Section 6.4  Setup Functions for Traction Controller 
 
FUNCTION 1  
MOTOR VOLTS TO ENABLE AUTO REGEN 
 (Push 
1) 
 
This function allows for the adjustment of motor volts to 
enable AutoRegen.   
 
For a setting value of less than 25 (corresponding to a soft 
release of auto regen and normal regen), the motor voltage 
to enable regen is calculated by multiplying the value of the 
setting by 0.375.  For example, a setting of 16 will be 
multiplied by 0.375 to enable regen at 6 motor volts.   
 
Vm = VAL(setting) X .375 
 
For a setting value of greater than 25, the motor voltage to 
enable auto regen is calculated by subtracting 25 from the 
setting value and multiplying that number by 0.375.  For 
example, a setting of 33, the motor volts necessary to 
enable auto regen is (33 - 25) x 0.375, or 3 volts. 
 
FUNCTION 2 
CREEP SPEED 
 (Push 
2) 
 
This function allows for the adjustment of the creep speed 
of the vehicle.  Creep speed can be adjusted when an 
accelerator input voltage between 3.9 and 3.3 volts or an 
accelerator ohm input between 6.0K and 4.0K ohms is 
provided. 
 
 
 
Range   
2% to 15% on-time 
 Set 
 0 
to 
255 
 
Resolution 
0.05% per set unit 
 
Example  
Setting of 20 = 3% on-time 
 
Important Note: This function is used to optimize motor 
and control performance, and this setting will be 
determined by GE and OEM engineers at the time of 
vehicle development. This setting must not be changed by 
field personnel without the permission of the OEM.
 
 
FUNCTION 3  
ARMATURE CONTROLLED 
ACCELERATION  
 (Push 
3) 
 
This function allows for the adjustment of the rate of time it 
takes for the control to accelerate to 100% applied battery 
voltage to the motor on hard acceleration.  
 
  
Range 
0.025 to 6.3 seconds 
 
Set 
0 to 255 
 
Resolution 
0.025 seconds per set unit 
 
Example: 
Setting of 20 = 0.5 seconds 
 
 
 
FUNCTION 4  
ARMATURE CURRENT LIMIT  
 (Push 
4) 
 
This function allows for the adjustment of the armature 
current limit of the control. The rating of the control will 
determine the range of adjustment for this function. Please 
refer to the specification sheets and current limit curves for 
the control used in your vehicle. 
 
 
Range 
See control C/L curves 
 
Set 
0 to 255 
 
Example: 
0 = min. current, 255 = max. 
 
 
 
current  
 
FUNCTION 5  
PLUGGING DISTANCE (CURRENT) 
 (Push 
5) 
 
This function allows for the adjustment of the plugging 
distance of the vehicle.  The larger the current setting, the 
shorter the stopping distance. 
  
Min Max Set 
Resolution 
 
Per Unit Value 
Example  
If Set at 20 
55 
455 
0 to 255 
1.57 amps 
86.4 amps 
 
Warning:  Plug settings must be made in accordance with 
control operating instructions.  Too high of a setting could 