GE IC3645SR4U404N2 Benutzerhandbuch

Seite von 74
ADJUSTABLE FEATURES 
SX TRANSISTOR CONTROLS
 
 
 
Page 
58
 
 
 
January 2000
   
FUNCTION 6  
FW RATIO 
 (Push 
6) 
 
This function sets the ratio between armature and field 
current when operating below the Field Weakening Start 
point.  The setting represents the quantity of field current 
changed for each 1 amp of armature current changed. 
 
Max Fld Ref 
Set 
Resolution Per Unit Value 
40 
0 to 10 
0.029 amps 
 
The ratio value (VAL) is the set value divided by 10 and 
rounded to the whole number. 
 
Example:  Setting of 45 = 45/10 = 4.5 = 4 VAL 
 
I
FIELD
 = VAL (I
MOTOR
 x 0.029) 
 
FUNCTION 7  
MIN FIELD CURRENT 
 
( Push 7 ) 
 
This function allows the adjustment of the field weakening 
level in order to set the top speed of the motor. 
 
 
Min  Max  Set 
Resolution Per Unit Value 
40 
51 to 255  0.185 
 
MIN  I
 = (VAL-51) X 0.185 
 
Important Note: This function is used to optimize motor 
and control performance, and this setting will be 
determined by GE and OEM engineers at the time of 
vehicle development. This setting must not be changed by 
field personnel without the permission of the OEM.
 
  
FUNCTION 8  
MAX FIELD CURRENT 
 
( Push 8 ) 
 
This function allows for the adjustment of the maximum 
field current in order to obtain the maximum torque of the 
motor. 
  
 
Min  Max  Set 
Resolution Per Unit Value 
40 
51 to 255  0.185 
 
MAX  I
 = (VAL-51) X 0.185 
 
Important Note: This function is used to optimize motor 
and control performance, and this setting will be 
determined by GE and OEM engineers at the time of 
vehicle development. This setting must not be changed by 
field personnel without the permission of the OEM. 
 
 
 
 
FUNCTION 9  
REGEN BRAKING C/L 
 (Push 
9) 
 
This function allows for the adjustment of the Regen 
braking current limit. High current correlates to shorter  
stopping distance. 
  
 
   
Resolution 
Example 
Min 
Max  Set 
Per unit value  If set at 20 
52A 
468A  0 to 255 
1.63 amps 
84.6 amps 
 
REGEN BRAKE I
A
 = (VAL X 1.63) + 52 
 
FUNCTION 10  
FIELD CURRENT FOR REGEN  
 
( Push 10 ) 
 
This function allows for the adjustment of the field current 
to be used during the regen braking mode. 
 
 
 
   
Resolution 
Example 
Min 
Max  Set 
Per unit value  If set at 71 
40 
51 to 255 
0.185 amps 
3.7 amps 
 
I
 = (VAL-51) X 0.185 
 
Important Note: This function is used to optimize motor 
and control performance and this setting will be 
determined by GE and OEM engineers at the time of 
vehicle development. This setting must not be changed by 
field personnel without the permission of the OEM. 
 
FUNCTION 11 
TURN SPEED LIMIT 
  (Push 
11) 
 
This function allows for the adjustment of the speed limit 
(maximum battery volts to the motor) when the SL1 signal is 
calculated from the turn angle potentiometer by the control 
card. 
 
Range   
100% to 0% battery volts 
Set 
 
51 to 180 
Resolution 
0.78% per set unit 
Example  
Setting of 71 = 84.4% of battery volts 
 
Note:  To disable speed limit, and assure no 1A hold off, set 
this function to a value of zero. 
 
FUNCTION 12  
MAX ARMATURE PERCENT ON 
 
( Push 12 ) 
 
Same as function 11, this function allows for the 
adjustment of the motor speed limit (maximum battery volts 
to the motor).  The dash display mode selection enables the 
speed limit as well as setting the level of speed limit.