The PCI-8570/PXI-8570 User's Manual (Rev. 1.00) section 2.4 contains the software installation instructions. These 
should be executed before allowing the hardware installation process to look for the driver. If you have an AdLink 
CD Version 2004A4 or later you can use it; if not you should download the latest driver from the WEB site 
(
). You can then continue with the Hardware Installation. A reboot will then be 
necessary. At this point the Stargen Fabric PCI Adapter and the Stargen Aruba Fabric-to-PCI Bridge should appear 
correctly installed under System Devices in the Device Manager. 
NOTE: If you have an AdLink CD Version 2005A3 or later you can find 8570install.exe in the folder X:\Driver 
Installation\PXI Platform\PXI Extension\PCI_PXI-8570\Wnt2kxp and the starfab1.inf file in the folder X:\Driver 
Installation\PXI Platform\PXI Extension\PCI_PXI-8570\Win98. 
2.2. 
Installing the Software under Windows 
2.2.1.  Warnings 
If Setup detects a previous installation of Acqiris software on your system, a warning screen will be displayed. It is 
recommended to exit Setup and uninstall older versions. 
The installer from software releases prior to Acqiris Software 2.0 installed the Digitizer Driver DLL files into the 
System directory. These will be removed by Setup. If you wish to keep the old installation on your system, you 
should exit Setup, and move all Acqiris driver files (acqiris*, acqrs* and acqir*) to some archive directory. 
The DLL files will be installed into the bin subdirectory of the Acqiris software root, and the corresponding path will 
be added to the PATH environment variable. 
2.2.2.  Multiple Versions 
With the software installation from Acqiris Software 2.0 (or above), it is possible to keep multiple versions on the 
same system, but you must specify a different root directory (i.e. Install Folder). If you keep the same directory, 
Setup will overwrite your previous installation. 
To go back to a previous version, you must change the PATH environment variable and reinstall the Kernel driver. 
Note that the 10-bit instruments are not supported by Kernel versions before 1.8 which was part of Acqiris Software 
2.13c. Under Windows 2000/XP,  
1.  Copy the SYS file from <old_AcqirisSoftware_root>\bin\kernel to the 
Windows\System32\drivers
 directory.  
2.  Change the AcqirisDxRoot, AcqirisDxDir and PATH environment variables to the old root.  
3.  Reboot the computer. 