Adder Technology TS4 Benutzerhandbuch

Seite von 19
4



Upgrading
Like all Adder products, the internal software (firmware) of the TS4 is designed 
to be easily upgraded in order to take advantage of a continual process of 
improvement and innovation. A specialised upgrade cable is required to 
connect the Adder TS4 to the serial port of a suitable system. The cable may be 
purchased from your supplier, direct from Adder or created using the 
 
given later in this guide.
You can discover the current version of your Adder TS4 in two ways, either using 
the upgrade application (discussed later) or within the configuration mode as 
discussed next.  
To discover the current firmware version
1  Enter configuration mode: Press and hold the 
SELECT
 button until the 
SYSTEM
 
readout shows c.
2  You need to discover the three digits of the firmware release individually, as 
follows:
•  Press     
 to discover the first firmware release digit.
•  Press     
 to discover the second firmware release digit.
•  Press     
 to discover the third firmware release digit.
  At each stage, the 
SYSTEM
 readout will momentarily show 
=
 and then the 
relevant digit, before returning to the c prompt. For example, the respective 
digits 1, 4 and 6 mean that the firmware version is v1.46. 
3  Once completed, press     to exit from configuration mode. 
To upgrade the Adder TS4
1  Download the latest TS4 firmware upgrade file from the Adder website: 
. The upgrade files are compressed using pkzip format 
which you will need to decompress them. If you do not have pkzip, go to 
 to download the latest version. Place the decompressed 
upgrade files onto the Windows system that will be connected (via a vacant 
serial port) to the Adder TS4 unit. 
2  Remove power from the Adder TS4. If any systems are active, either switch 
them off or remove their keyboard link connectors from the Adder TS4. If an 
optional power supply is used, remove it.
3  Connect the upgrade cable between the remote control socket on the end 
of the Adder TS4 unit adjacent to the Adder logo, and a vacant serial port 
on the system containing the upgrade files. 
4  On the underside of the unit, click mini switch 7 to its ON position.
5  Re-apply power to the Adder TS4 and switch on the system to be used for 
the upgrade. The 
SYSTEM
 readout will show  . 
7  Click the Browse... button and locate the TXT file that accompanied the 
upgrade utility. Highlight the TXT file and click the Open button.
8  Click the 
Advanced... button and in the subsequent dialog, ensure that the 
Serial Port entry matches the port to which the upgrade cable is attached. 
Also select the Program and verify option. Click the OK button.
9  Click the Query Unit button to check the name and version of the current 
firmware - the application will interrogate the TS4 via the upgrade cable. 
Once the version information is displayed, check that the Intended Target 
Units
 field matches the Unit Connected field and the New Firmware Version 
field exceeds that of the Current Firmware Version.
10  Click the Upload Now button to begin transferring the upgrade data from 
the system to the Adder TS4. The progress of the upload is shown in the 
status bar (indicating the advancement of the current task) and the progress 
bar (indicating the progress of the upload as a whole). The 
SYSTEM
 readout 
will show u.
   During the upload, all buttons become disabled except for the Abort 
button. The upload can take as long as fifteen minutes. Should you need to 
abandon the upload at any stage, click the Abort button.  
   Following the upload, a verification will be carried out and the results 
displayed within the upgrade application window. 
11  When complete, switch off the Adder TS4, disconnect the upgrade cable, 
return mini switch 7 to its OFF position and resume operation of the Adder 
TS4 in the usual manner.
6  Locate and run the application ‘KVMUploader’ to display this window: