Troubleshooting
If you experience problems when installing or using the Adder TS4, please check 
through this section for a possible solution. If your problem is not listed here 
and you cannot resolve the issue, then please refer to the ‘Getting assistance’ 
section.
Mouse does not move cursor on screen.
•  If you move the mouse and the activity indicator (dot on 7 segment display) 
does not flash then the Adder TS4 is not receiving data from the mouse. 
Check the mouse connection to the Adder TS4, try resetting the mouse 
using the reset function or re-powering the Adder TS4. If you are attempting 
to connect the Adder TS4 to a system with a PS/2 mouse connection 
that has not been powered down then you will need to use the mouse 
restoration functions.
Keyboard does not function or functions intermittently. Num lock light 
does not always come on when the num lock key is pressed.
•  Some older keyboards were designed for use with specific systems and 
are not truly AT or PS/2 compatible. These are not common but if you 
experience problems try another keyboard.
Mouse causes channel to change.
•  Some cheaper mice are not fully compatible with the Adder TS4 and can 
lose data causing the channel to be changed (if mouse switching of channels 
is enabled). Ensure that you are using a Microsoft compatible mouse driver 
on your system. Some other manufacturers’ drivers may switch the mouse to 
use a proprietary mouse data format not supported by the Adder TS4. If you 
have unplugged and re-connected a mouse to the Adder TS4 then ensure 
that you reset it using the mouse reset function.
Mouse jumps around the screen after disconnecting the mouse cable or 
powering down the Adder TS4.
•  The mouse data format may be out of synchronisation with that required by 
the system (PS/2 or Intellimouse). Try the ‘restore Intellimouse’ function (F6) 
to resolve the problem or repower the system.  
Getting assistance
If you are still experiencing problems after checking the list of solutions in the 
Troubleshooting section then we provide a number of other solutions:
• 
Adder.Technology.website.– 
  Check the Support section of our website for the latest solutions.
•  
Email.
•  
Fax..
in the UK: 
054 00
   
in the US:  
+  5 
• 
Phone.. in the UK:  
054 0044
   
in the US:  
+  3 333
SECT 5
Upgrade cable pin out