Netgear M5300-28G-POE+ (GSM7228PSv1h2) - 12-Port Managed Gigabit Switch Softwarehandbuch

Seite von 1265
Utility Commands 
306
M5300, M6100, and M7100 Series ProSAFE Managed Switches 
cablestatus
This command returns the status of the specified port.
Power Management Commands
Note:
Power management commands are supported on the M6100 series 
switches only.
power auto-rebalance
This command enables chassis automatically re-adjusts power allocation to the blades such 
that lowest priority port on the chassis gets automatically shut down and higher priority ports 
on the chassis are powered.
  no power auto-rebalance
This command disables auto power rebalance among blades in the chassis. 
Format
cablestatus unit/slot/port
Mode
Privileged EXEC
Field
Description
Cable Status
One of the following statuses is returned:
• 
Normal
. The cable is working correctly.
• 
Open
. The cable is disconnected or there is a faulty connector.
• 
Short
. There is an electrical short in the cable.
• 
Cable Test Failed
. The cable status could not be determined. The cable may in fact be 
working.
Cable Length
If this feature is supported by the PHY for the current link speed, the cable length is displayed as a 
range between the shortest estimated length and the longest estimated length. Note that if the link is 
down and a cable is attached to a 10/100 Ethernet adapter, then the cable status may display as 
Open or Short because some Ethernet adapters leave unused wire pairs unterminated or grounded. 
Unknown is displayed if the cable length could not be determined.
Default
disabled
Format
power auto-rebalance
Mode
Chassis Global Config
Format
no power auto-rebalance
Mode
Chassis Global Config