Netgear M5300-28G-POE+ (GSM7228PSv1h2) - 12-Port Managed Gigabit Switch Softwarehandbuch

Seite von 764
Configure Switching Information 
302
M6100, M5300, and M7100 Series Managed Switches 
The range is 1 to 65535 seconds. The default is 50000.
13. 
Configure the Tx Interval in milliseconds between the DCPDP messages transmitted. 
The range is 200 to 4000 milliseconds.
14. 
Configure the Rx Timeout, which is the DCPDP reception time-out in milliseconds. 
The range is 700 to 14000 milliseconds.
15. 
Click the Apply button.
The switch is updated with the values you entered. Configuration changes take effect 
immediately.
The following table describes the nonconfigurable Peer Detection field.
Configure the Virtual Port Channel Interface
You can configure the VPC interfaces on the device. You create a VPC interface by 
combining a port channel on the local device with a port channel on the peer device. The 
VPC interface on the local and peer devices share a common VPC identifier. You can 
configure multiple instances of VPC interfaces on each peer device in the VPC domain.
Configure the VPC interface:
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
The Login screen displays.
5. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.
Table 114.  Peer Detection
Field
Description
Peer Detection Status
Displays whether peer detection is enabled or disabled.
Operational Tx Interval
The operational transmit interval in milliseconds.
Operational Rx Timeout
The operational time-out value in milliseconds.