Configure System Information
32
M6100, M5300, and M7100 Series Managed Switches
View the Temperature Sensor Information
You can view the current temperature of the temperature sensors. The temperature is instant
and can be updated with the latest information on the switch when the Update button is
clicked. The maximum temperature of the temperature sensors depends on the actual
hardware.
and can be updated with the latest information on the switch when the Update button is
clicked. The maximum temperature of the temperature sensors depends on the actual
hardware.
To view temperature information:
1.
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for
example, 169.254.100.201.
2.
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on
the switch.
3.
Launch a web browser.
4.
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
5.
Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
do not enter a password.
6.
Click the Login button.
The web management interface menu displays.
7.
Select System > Management > System Information > Temperature Sensors.
To refresh the screen, click the Update button.
The following table describes the nonconfigurable Temperature Status information.
Table 5. Temperature Status information
Field
Description
Unit ID
The unit number in the chassis.
Temp (C)
The temperature of the specified unit in degrees Centigrade.
State
The unit temperature state.
Shutdown Temp (C)
The shutdown temperature value. Once the blade exceeds this limit,
the chassis shuts down the the power for this blade.
the chassis shuts down the the power for this blade.