Configure System Information 
33
 M6100, M5300, and M7100 Series Managed Switches
View the Fan Status
This screen shows the status of the fans in all units. These fans remove the heat generated 
by the power, CP,U and other chipsets, and allow the chipsets work normally.
To view the fan status:
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
The Login screen displays.
5. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.
7. 
Select Management > System Information > Fan Status.
Fan status has three possible values: OKFailure, and Not Present.
The following table describes the nonconfigurable Fan Status information.
To refresh the screen, click the Update button.
Table 6.  Fan Status
Field
Description
Fan
The fan index used to identify the fan for the given chassis member.
Type
Specifies whether the fan module is fixed or removable.
Speed
The fan speed.
Duty Level
The duty level of the fan.
State
Specifies whether the fan is running or stopped.