Honeywell HE360 Installationsanleitung

Seite von 40
HE360 HUMIDIFIER AND INSTALLATION KIT
69-2631ES—03
16 
Fig. 13. Cleaning your humidifier.
7. Disconnect the drain hose from the drain fitting on the bottom of the humidifier 
housing.
8. Clean the drain fitting, if necessary.
9. Bend the drain hose to loosen any mineral deposits.
10. Flush the drain hose with pressurized water (a running tap) to clean the hose.
11. Reattach the drain hose to the drain fitting.
12. Snap the water nozzle back on the tray.
13. Be sure the marked end of the pad is facing up. Place the tray on the new pad.
14. Place the humidifier pad assembly in the humidifier housing. Be sure the water 
feed tube is placed in the guide slots.
15. Replace the humidifier cover.
16. Verify the humidifier operation by following the steps in the Checking Your 
Humidifier for Correct Operation section.
CHECKING YOUR HUMIDIFIER FOR 
CORRECT OPERATION
After winter startup or servicing, use the following steps to check your humidifier 
operation:
1. Turn on the humidifier power and water supply.
2. Turn the humidistat to its highest setting and set the thermostat to 10°F (6°C) 
above the room temperature.
3. Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be running to activate the humidifier.
4. Reset the thermostat and humidistat to a comfortable setting for automatic oper-
ation.
M12809
COVER 
ASSEMBLY
HUMIDIFIER 
PAD ASSEMBLY
FEED TUBE NOZZLE
WATER 
DISTRIBUTION TRAY
HUMIDIFIER
HOUSING
THUMB 
SCREW