HE360 HUMIDIFIER AND INSTALLATION KIT
17
69-2631ES—03
TROUBLESHOOTING YOUR HUMIDIFIER
Table 3. Troubleshooting Humidifier.
Problem
What to look for
What to do
Water leakage
Leaking joints.
Shut off water.
Tighten connections.
Brass tubing inserts Verify that brass tubing inserts are used.
Saddle valve leaking. Verify rubber pad is installed on saddle 
valve.
No water to drain.
Electrical
Verify control circuit wiring.
Check all connections.
Humidistat
Turn humidistat up and down and listen for 
contact to click.
Humidifier power Verify that outlet has power.
Solenoid
After verifying other wiring components, 
turn on furnace fan, turn humidistat up and 
down, and listen for solenoid to click.
Plumbing
Verify plumbing connections.
Check for kinks.
Saddle valve
Verify that needle pierces water line and 
then backs out needle to open valve.
Humidifier
Remove cover and verify that water flows 
into distribution tray.
Drain tubing
Verify no obstructions.
Low humidity
Furnace blower 
not operating.
• Reset circuit breaker or check for blown 
fuse.
• Check that the furnace power is on.
• Check all external wiring connections.
• Check the humidity control setting.
• Call a professional heating contractor.
Rapid air 
changes. Drafts 
(cold air is dry and 
is an added load 
to the humidifier).
• Keep doors and windows closed.
• Close fireplace damper when not in use.
• Keep exhaust fan running time to a 
minimum.
• Seal around doors and windows.
High humidity
Condensation on 
walls.
• Turn off humidity control and water until 
condensation is completely evaporated.
Heavy 
condensation on 
windows.
• Turn humidity control down low enough 
to eliminate condensation caused by 
moisture from bathing, mopping, 
cooking, etc. If moisture persists, more 
ventilation is needed.