Honeywell HE360 Installationsanleitung
HE360 HUMIDIFIER AND INSTALLATION KIT
3
69-2517EF—01
Fig. 2. Selecting duct location for humidistat.
Locating Closest 120V Electrical Outlet
• Select location with access to an outlet. If not
available, contact an electrician to have one installed.
• Make sure that the humidifier cord is adequate to
reach from the humidifier to the outlet.
• Make sure that the 20 ft (6.2m) of thermostat wire is
adequate to reach from the humidifier solenoid, to the
sail switch, to the humidistat.
sail switch, to the humidistat.
Installing the Humidifier
WARNING
Hazardous Voltage
Can cause personal injury or equipment
damage.
Do not cut or drill into any air conditioning or
electrical accessory.
Can cause personal injury or equipment
damage.
Do not cut or drill into any air conditioning or
electrical accessory.
CAUTION
Sharp Edges Installation Hazard.
Can cause personal injury.
Wear gloves and safety glasses.
Can cause personal injury.
Wear gloves and safety glasses.
1. Turn off power to the air handing system at the cir-
cuit breaker.
2. Draw a level line on the plenum in the location
chosen for the humidifier. (Leveling assures optimal
humidifier performance.)
humidifier performance.)
3. Locate the template (form number 69-1651
included in the box).
4. Tape the template in position and trace around
the template.
5. Remove the template and carefully cut the rect-
angular opening.
6. Disassemble the humidifier; remove the cover and
take out the humidifier pad assembly. See Fig. 3.
Fig. 3. Disassembling humidifier.
7. Position the securing clips as shown in Fig. 4.
Fig. 4. Position securing clips.
8. Make sure the humidifier housing is level, then posi-
tion it in the opening so the plastic tabs are in place
on the lower sheet metal edge of the opening. Use
pliers, as necessary, to flatten cut edges. See Fig.
5.
on the lower sheet metal edge of the opening. Use
pliers, as necessary, to flatten cut edges. See Fig.
5.
9. Push in securing clips until completely seated.
10. Drill holes and install the three sheet metal screws
on the top of the humidifier housing. Secure the
housing with the three remaining screws.
housing with the three remaining screws.
ALTERNATE LOCATION
RETURN
AIR
AIR
RETURN
AIR
AIR
6 in. (152 mm)
MINIMUM
15 in. (381 mm)
MINIMUM
BEST
LOCATION
LOCATION
RETURN AIR DUCT
M12831A
M12809
COVER
ASSEMBLY
ASSEMBLY
HUMIDIFIER
PAD ASSEMBLY
PAD ASSEMBLY
FEED TUBE NOZZLE
WATER
DISTRIBUTION TRAY
DISTRIBUTION TRAY
HUMIDIFIER
HOUSING
HOUSING
THUMB
SCREW
SCREW
M12813
CLIP
CLIP