7. Disconnect the drain hose from the drain fitting on 
the bottom of the humidifier housing.
8. Clean the drain fitting, if necessary.
9. Bend the drain hose to loosen any mineral deposits.
10. Flush the drain hose with pressurized water (a run-
ning tap) to clean the hose.
11. Reattach the drain hose to the drain fitting.
12. Snap the water nozzle back on the tray.
13. Be sure the marked end of the pad is facing up. 
Place the tray on the new pad.
14. Place the humidifier pad assembly in the humidifier 
housing. Be sure the water feed tube is placed in 
the guide slots.
15. Replace the humidifier cover.
16. Verify the humidifier operation by following the 
steps in the Checking Your Humidifier for Correct 
Operation section.
CHECKING YOUR 
HUMIDIFIER FOR CORRECT 
OPERATION
After winter startup or servicing, use the following steps to 
check your humidifier operation:
1. Turn on the humidifier power and water supply.
2. Turn the humidistat to its highest setting and set the 
thermostat to 10°F (6°C) above the room tempera-
ture.
3. Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be running to activate 
the humidifier.
4. Reset the thermostat and humidistat to a comfort-
able setting for automatic operation.