Honeywell HE360 Installationsanleitung

Seite von 20
HE360 HUMIDIFIER AND INSTALLATION KIT
69-2517EF—01
6
Fig. 11. Humidistat base and rear view.
WIRING
CAUTION
Hazardous Voltage. 
Can cause personal injury or equipment 
damage.
Disconnect power supply before installing or 
servicing equipment.
IMPORTANT
All wiring must comply with applicable local 
code, ordinances and regulations.
Wire the humidifier solenoid valve, pressure switch, 
humidistat and transformer.See Fig. 13.
Fig. 12. Wiring the controls.
Fig. 13. Close-up of pressure switch wiring.
1. Run the two-strand thermostat wire from the humid-
ifier to the humidistat, and from the humidistat to the  
pressure switch and back to complete the wiring 
loop to the humidifier. This is illustrated in Fig. 12.
2. Cut lengths of thermostat wire to reach between 
components, leaving adequate wire at both ends for 
connections.
NOTE: Humidistat and pressure switch can be wired in 
any order.
3. At the humidifier, connect the black and white con-
ductors to the two yellow humidifier wires. (The red 
wires from the humidifier are not used.)
4. At the humidistat, connect both black conductors to 
the two humidistat terminals. Use a wire nut to con-
nect together the two white conductors.
TESTING HUMIDIFIER 
OPERATION
Checklist
Humidifier is level.
Control wiring was reviewed using circuit diagram.
Humidifier is plugged in.
Feed line has no kinks.
Drain line slopes continuously down and ends at floor 
drain.
Water hose inside humidifier is connected to 
PerfectFlow™ water distribution tray.
After installation use the following steps to check the 
humidifier operation:
1. Turn on the power and the water supply
2. Turn the H8908 Humidistat to On and turn on the 
heat by setting the thermostat to 10ºF (6ºC) above 
room temperature.
IMPORTANT
The furnace blower must be on to activate the 
humidifier.
3. Make sure that water is flowing out of the drain 
hose. If water does not flow, see Troubleshooting 
Your Humidifier section.
4. Check for leaks.
5. Reset the thermostat and H8908 Humidistat to a 
comfortable setting for automatic operation.
M20179
WIRE SLOT
HUMIDISTAT WIRES
HUMIDISTAT BASE
REAR OF HUMIDISTAT
Humidity Control
Régulateur d'humidité
-20 ¡F
-10 ¡F
0 ¡F
+10 ¡F
+20 ¡F
Over 20 ¡F
15%
20%
25%
30%
35%
40%
HUMIDITY
SETTING
OUTDOOR
TEMPERATURE
-30 ¡C
-25 ¡C
-20 ¡C
-10 ¡C
-5 ¡C
Over 0 ¡C
M28969
BLACK
WHITE
HUMIDIFIER
SOLENOID
VALVE
HUMIDISTAT
AIR PRESSURE 
SWITCH
ATTACH
ADAPTOR
WIRE TO HVAC
C TERMINAL
M27398A
COMMON (C) TERMINAL
1/4 (6) X 1/32 (1) THICK
QUICK CONNECT
NORMALLY OPEN (NO) 
TERMINAL 1/4 (6) X 1/32 (1) 
THICK QUICK CONNECT
ATTACH ADAPTER
WIRE TO HUMIDIFIER
C TERMINAL
C
1
2
3
1
2 3
2
3
NC
NO
+
PI
ASSEMBLED
IN MEXICO