Honeywell HE360 Installationsanleitung

Seite von 8
HE360 HUMIDIFIER INSTALLATION KIT
3
69-1572
4.
Tape the template in position and trace around the 
template. 
5.
Remove the template and carefully cut the rectan-
gular opening.
6.
Disassemble the humidifier; remove the cover and 
take out the humidifier pad assembly. See Fig. 3.
Fig. 3. Disassembling humidifier.
7.
Make sure the humidifier housing is level, then 
position it in the opening so the plastic tabs are in 
place on the 
lower sheet metal edge
 of the open-
ing. Use pliers, as necessary, to flatten cut edges. 
See Fig. 4.
8.
Secure the humidifier housing to the opening at the 
top and bottom using sheet metal screws. 
Fig. 4. Installing humidifier on duct.
9.
Reinstall the humidifier pad assembly in the humid-
ifier housing.
IMPORTANT
Be sure to reconnect the water feed tube and 
ensure that the tube is not pinched or kinked.
10.
Hinge the cover in place and secure with the 
thumbscrew located at the bottom of the cover.
CONNECTING PLUMBING
Use hot or cold water and either hard or softened water 
in the humidifier.
1.
Shut off the water.
CAUTION
Chemical Hazard. 
Can cause personal injury or equipment 
damage.
Do not use any line connected to an air 
conditioner. 
Do not use gas line.
2.
Use the self-piercing saddle valve (included) to tap 
into the water supply line at the location selected. 
See Fig. 5. If tapping into galvanized pipe, drain 
line and pre-drill 3/17 in. tap for saddle valve.
NOTE:
The saddle valve is not designed to regulate 
water flow. The valve is either open or closed.
IMPORTANT
To prevent debris from clogging the solenoid in-
line filter, be sure to install the saddle valve han-
dle pointing toward the ceiling.
Fig. 5. Installing saddle valve.
3.
Use 1/4 in. (6 mm) OD tubing and connect the sad-
dle valve to the inlet side of the solenoid valve (see 
Fig. 6).
a. Place the brass compression nut over the 
tubing.
b. Install brass insert into end of tubing.
c. Slide the plastic compression ring over the   
tubing. (Discard copper compression ring pro-
vided with valve.)
NOTE:
To prevent leaking, use plastic (Delrin) sleeve 
rings with plastic tubing. Use copper sleeve 
rings only with copper tubing.
M12809
COVER 
ASSEMBLY
HUMIDIFIER 
PAD ASSEMBLY
FEED TUBE NOZZLE
WATER 
DISTRIBUTION TRAY
HUMIDIFIER
HOUSING
THUMB 
SCREW
DUCT
LEVEL
SHEET METAL
SCREWS (4)
PLASTIC
TABS (2)
DRAIN TUBING
M20204
OPENING
TO AIR DUCT
M20175
SCREW DRIVER
WATER LINE