TROUBLESHOOTING YOUR HUMIDIFIER (TABLE 2)
Table 2. Troubleshooting Humidifier.
Problem
What to look for
What to do
Water leakage
Leaking joints.
Shut off water.
Tighten connections.
Brass tubing inserts
Verify that brass tubing inserts are 
used.
Saddle valve leaking.
Verify rubber pad is installed on 
saddle valve.
No water to drain.
Electrical
Verify control circuit wiring.
Check all connections.
Humidistat
Turn humidistat up and down and 
listen for contact to click.
Humidifier power
Verify that outlet has power.
Sail switch
Remove sail cover; turn on furnace 
fan and listen for faint click.
Verify that sail can move freely in 
duct; check sail switch instructions 
to trim sail, if necessary.
Solenoid
After verifying other wiring 
components, turn on furnace fan, 
turn humidistat up and down, and 
listen for solenoid to click.
Plumbing
Verify plumbing connections.
Check for kinks.
Saddle valve
Verify that needle pierces water 
line and then backs out needle to 
open valve.
Humidifier
Remove cover and verify that water 
flows into distribution tray.
Drain tubing
Verify no obstructions.