Honeywell HE360 Installationsanleitung

Seite von 8
HE360 HUMIDIFIER INSTALLATION KIT
69-1572
6
1.
Run the two-strand thermostat wire from the 
humidifier to the humidistat, and from the humidis-
tat to the sail switch.
2.
Cut lengths of thermostat wire to reach between 
components, leaving adequate wire at both ends 
for connections.
NOTE:
Humidistat and sail switch can be wired in any 
order.
3.
At the humidifier, connect the black and white con-
ductors to the two yellow humidifer wires. (The red 
wires from the humidifier are not used.)
4.
At the humidistat, connect both black conductors to 
the two humidistat terminals. Use a wire nut to con-
nect together the two white conductors.
5.
At the sail switch, connect the black and white con-
ductors to the Com and NO sail switch terminals 
(NC terminal is not used).
TESTING HUMIDIFIER OPERATION
Checklist
Humidifier is level.
Control wiring was reviewed using circuit diagram.
Humidifier is plugged in.
Feed line has no kinks.
Drain line slopes continuously down and ends at floor 
drain.
Water hose inside humidifier is connected to 
PerfectFlow™ water distribution tray.
After installation use the following steps to check the 
humidifier operation:
1.
Turn on the power and the water supply
2.
Turn the H8908 Humidity Control to On and turn on 
the heat by setting the thermostat to 10ºF (6ºC) 
above room temperature.
IMPORTANT
The furnace blower must be on to activate the 
humidifier.
3.
Make sure that water is flowing out of the drain 
hose. If water does not flow, see Troubleshooting 
Your Humidifier section.
4.
Check for leaks.
5.
Reset the thermostat and H8908 Humidity Control 
to a comfortable setting for automatic operation.