Samsung SHR-6160P Benutzerhandbuch

Seite von 105
22_
 
connecting with other device
connecting with other device
CONNECTING THE RS-485 DEVICE
Connect the RS-485 device through the back port.
For example, you can connect and control the PTZ 
camera which supports the RS-485 
communication.
Transfer Type : You may select either Half Duplex or Full 
Duplex as the data transfer type.
Baud Rate : Supported Baud rates are 600/1200/2400/
4800/9600/19200/38400.
Check if the RS-485 device is compatible with the 
product fi rst.
Pay attention not to change the polarity (+/-) of the 
RS-485 device when connecting it.
Depending on camera’s type, connection polarity can be 
different.
For further information, refer to the respective PTZ 
Camera’s documentation.
Ex : DVR(TX+/-) 
↔ SCC-C6433,35(RX+/-)
 DVR(TX+/-) 
↔ SCC-C6403,07(TX+/-)
M
M
PTZ device 
Half Duplex Type
 Data 
(–)
 Data 
(+)
Full Duplex Type
 Rx(+)
 
 Rx(–)
 Tx(–)
 Tx(+)
 
    
  
Rear
Tx(–)
  
Tx(+)
Rx(–)
  
 
Rx(+)