Troubleshooting
Refer to the following chart if the air conditioner operates abnormally. This may save 
time and unnecessary expenses.
PROBLEM
SOLUTION
The air 
conditioner does 
not work at all.
•  Check power status and then operate the air conditioner
   again.
•   Plug in or switch on the circuit breaker and then operate the
air conditioner again.
•   Check if you have set the Off Timer. Operate the air
conditioner again by pressing the Power button.
The temperature 
adjustment is not 
working.
•   Check if you have selected Dry/Fan/Turbo/d'light Cool
mode. In these modes, desired temperature is set to auto 
and you cannot adjust the temperature.
Cool/Warm air 
does not come 
out of the air 
conditioner.
•   Check if the set temperature is higher(during Cool mode)/
lower(during Heat mode) than the current temperature. 
Press the Temp hr. + or  button on the remote controller to 
change the set temperature.
•   Check if the Full HD filter is blocked by dirt. If there is a lot of
dust on the Full HD filter, cooling(heating) performance may 
decrease. Clean them frequently.
•   Check if the outdoor unit is covered or installed near the
obstacle. Take the cover off and take the obstacle away.
•   If you want to operate the air conditioner in the sunlight,
cover the outdoor unit using curtains or etc.
•   Check if the air conditioner is operating in De-ice mode.  
When the ice formed in winter or the outdoor temperature 
is too low, the air conditioner operates in De-ice mode 
automatically. In De-ice mode, indoor fan stops and cool air 
does not come out. 
•   If the doors or windows are open, it may cause bad cooling
(heating) performance.  
Close the doors and windows.
•   Check if the air conditioner has just been turned on after
stopping cooling or heating operation. In this case, just a fan 
will run to protect the outdoor unit compressor.
•   Check if the pipe length is too long. When the pipe length
exceeds maximum allowable pipe length, cooling (heating) 
performance may decrease.
Junfrau EU_AR09FSSK&Y@_IB_DB68-03363A_EN.indd   26