Lantronix LX6 Benutzerhandbuch

Seite von 74
XPort® Pro Lx6 Embedded Device Server User Guide
27
6: Line and Tunnel Settings
The XPort Pro Lx6 embedded device server contains one line using a standard RS232/RS485 
serial port.  This line may be configured to operate in the following modes:
RS232
RS485 Full Duplex (also compatible with RS-422)
RS485 Half Duplex, with and without termination impedance
All serial settings such as Baud Rate, Parity, Data Bits, etc, apply to these lines.
Line Settings
The Line Settings allow configuration of the serial lines (ports).
Some settings may be specific to only certain lines.  Such settings are noted below.
Table 6-1  Line Configuration Settings
Line Settings
Description
Name
Enter a name or short description for the line, if desired.  By default, there is 
no name specified.  A name that contains white space must be quoted.
Interface
Set the interface type for the Line.  The default is RS232 for Line 1.
Choices are:
RS232 
RS485 Full-Duplex 
RS485 Half-Duplex 
Termination
Select to Enable or Disable Line Termination. The default is Disable.
Note:
This setting is only relevant for Line 1 with Interface type RS485 Half-
Duplex.
State
Select to Enable or Disable the operational state of the Line.  The default is 
Enable.
Protocol
Set the operational protocol for the Line. The default is Tunnel. Choices are:
None
Tunnel = Serial-Network tunneling protocol.
Baud Rate
Set the Baud Rate (speed) of the Line.  The default is 9600.
Any set speed between 300 and 921600 may be selected: 300, 600, 1200, 
2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 921600.  When 
selecting a Custom baud rate, you may manually enter any value between 
300 and 921600.  
Note:
 Custom baud rates are not supported when a line is configured for 
Command Mode. 
Parity
Set the Parity of the Line. The default is None.
Data Bits
Set the number of data bits for the Line. The default is 8.
Stop Bits
Set the number of stop bits for the Line. The default is 1.
Flow Control
Set the flow control for the Line. The default is None.