6: Line and Tunnel Settings
XPort® Pro Lx6 Embedded Device Server User Guide
28
Table 6-2  Line Command Mode Settings
To Configure Line Settings
The following section describes the steps to view and configure Line 1 settings; these steps apply 
to other line instances of the device.
Using Web Manager
To configure a specific line, click Line in the menu and select Line 1 -> Configuration (
).
Xon Char
Set Xon Char to be used when Flow Control is set to Software.  Prefix decimal 
with \ or prefix hexadecimal with 0x or prefix a single control character 
<control>.
Xoff Char
Set Xoff Char to be used when Flow Control is set to Software.  Prefix decimal 
with \ or prefix hexadecimal with 0x or prefix a single control character 
<control>.
Gap Timer
Set the Gap Timer delay to Set the number of milliseconds to pass from the 
last character received before the driver forwards the received serial bytes.  
By default, the delay is four character periods at the current baud rate 
(minimum 1 msec).  Gap Timer range is 1 to 5000 milliseconds (default value 
is 4000 msec).
Threshold
Set the number of threshold bytes which need to be received in order for the 
driver to forward received characters.  Default value is 56 bytes.
Line Command 
Mode Settings
Description
Mode
Set the Command Mode state of the Line.  When in Command Mode, a CLI session 
operates exclusively on the Line. Choices are:
Always
Use Serial String
Disabled
Note:
In order to enable Command Mode on the Line, Tunneling on the Line must 
be Disabled (both Connect and Accept modes). Also, custom baud rates are not 
supported in Command Mode.
Wait Time
Enter the amount of time to wait during boot time for the Serial String.  This timer 
starts right after the Signon Message has been set on the Serial Line and applies 
only if mode is “Use Serial String”.
Serial String
Enter the Text or Binary string of bytes that must be read on the Serial Line during 
boot time in order to enable Command Mode.  It may contain a time element to 
specify a required delay in milliseconds x, formed as {x}.  Applies only if mode is 
“User Serial String”.  It may contain a binary character(s) of the form [x].  For 
example, use decimal [12] or hex [0xc].
Echo Serial String
Select Enable or Disable for Echo Serial String.  Applies only if mode is “User Serial 
String”.  Select enable to echo received characters backed out on the line while 
looking for the serial string.
Signon Message
Enter the string of bytes to be sent to the Serial Line during boot time.  It may contain 
a binary character(s) of the form [x].  For example, use decimal [12] or hex [0xc].
Line Settings 
Description