Honeywell CM921 Benutzerhandbuch

Seite von 7
CM921 CHRONOTHERM
 
 

EN0H 8557 UK07 R0 09/06 
 
 
 
SPECIFICATIONS 
CONTROLS/DISPLAY LAYOUT
 
ELECTRICAL
 
Room unit power 
supply 
:  2 x 1.5 V IEC LR6 (AA) Alkaline cells 
Battery life 
:  Minimum 2 years   
Battery 
replacement 
:  Program retained in EEPROM 
Receiver power 
supply 
:  230V AC +10% - 15%, 50Hz 
Switch type 
:  SPDT potential free 
Output rating 
:  24-230 V AC, 10 A resistive, 3 A inductive 
0.6 p.f.   
Wiring (receiver 
only) 
:  Cable terminals for mains and relay wiring 
for max 2.5 mm
2
 wire 
Wire access 
:  from the rear (wall box mounting), right 
and bottom 
RF 
RF operation band 
:  ISM (868.0-868.6) MHz, 1% duty cycle 
RF communication 
range 
:  30 m in a residential building environment 
RF communication 
technology 
:  short, high rate transmissions to minimise 
air time and avoid collisions 
Blocking immunity 
:  Receiver class 2 (ETSI EN300 220-1 
version 1.3.1) 
RF binding method 
:  Factory pre-bound with the room unit.  
ENVIRONMENTAL & STANDARDS 
Operating 
temperature 
:  0 to 40
o
C when relay load <  8 A 
:  0 to 30
o
C when relay load > 8 A 
Shipping & storage 
temperature 
:  -20 to 55
o
Humidity 
:  Humidity range 10 to 90% rh, non-
condensing 
IP class 
: 30 
Meeting the 
following 
standards 
:  EN60730-1(Nov 2000), EN55014-1(1997), 
EN55014-2(2000), ETSI EN300 220-3 
(2000), ETSI EN301 489-3(2000) 
TEMPERATURE CONTROL 
Sensing element
:  100K (@ 25
 o
C ) NTC thermistor 
Control form 
:  Fuzzy Logic Algorithm 
Minimum ON 
time 
10% of cycle time (min one minute), 
adjustable to 2 to 5 min (see installer set 
up) 
Cycle rate 
:  Selectable by application (see installer 
set up) 
Temperature 
control accuracy 
+
0.5 K (nominal) @ 20
o
C, 50% load 3K 
Δ/hour  
Fail-safe mode 
:  Off or cycling depending on the CM927 
system set-up 
TIME SETTING/PROGRAMMING 
Time display 
:  24 hour or 12 hour AM/PM format 
Time keeping 
accuracy 
:  Typically better than 10 minutes per year 
Program  
:  1-day with 6 daily time and temperature 
level changes 
Time setting 
resolution 
:  Time of day - 1 minute                 
Program – 10 minute steps 
Temperature 
setting range 
:  Program  : 5 to 35
o
C in 0.5 
o
C steps Frost 
 
     : 5
 o
C or equal to lower limit (5
 
o
C to 16
 o
C). Frost protection does not 
work in cooling mode 
Room 
Temperature 
display range 
: From 0
 o
C to 50
 o
C  
 
Room Unit Layout: 
 
1. 
Day & Date Display 
2. Time 
Display 
3. 
Dynamic Text Display 
(DTD) 
4. 
Burner On Indicator 
5. 
Battery Low Indicator 
6. Temperature 
Display 
7. Temperature 
Change 
Buttons 
8. Information 
Enquiry 
Button 
9. Slider 
Switch 
10. 
Green OK Button 
11. Program 
Buttons 
12. Battery 
Cover 
13. Battery 
Compartment 
14. Holiday 
Button 
15. 
Time Change Buttons