Rohde & Schwarz Inc NV830X Benutzerhandbuch
Chapter 8
Service
2098.0188.72
- 8.16 -
E-1
Fig. 12
Removing R&S NetCCU800 from transmitter rack
1) Captive screws at front panel of installed units (here: exciter and R&S NetCCU800)
2) Screws securing R&S NetCCU800 to rackmount
3) Guide rails
4) Support bracket for R&S NetCCU800
5) Safety lever for releasing guide rail catch
2) Screws securing R&S NetCCU800 to rackmount
3) Guide rails
4) Support bracket for R&S NetCCU800
5) Safety lever for releasing guide rail catch
6. Undo the two fastening screws (Torx screwdriver No. 9) from the rackmount on both
sides of the R&S NetCCU800.
Note
Removal should be performed by two persons. When pulled out by the handles, the R&S
NetCCU800 must be supported from below as soon as the support brackets no longer
support it.
NetCCU800 must be supported from below as soon as the support brackets no longer
support it.
7. Pull the R&S NetCCU800 out of the rackmount.
5.1.2
Preparing R&S NetCCU800 for Installation
The replacement R&S NetCCU800 is delivered as a desktop unit and must be prepared for
installation as follows.
installation as follows.
Remove the protective rubber caps on the rear feet of the instrument.
The replacement unit is as a rule preconfigured with the default configuration. So that the
new R&S NetCCU800 does not adversely affect the operation of the transmitter when it is
put into operation in the transmitter rack, it must first be configured specifically for the trans-
mitter.
new R&S NetCCU800 does not adversely affect the operation of the transmitter when it is
put into operation in the transmitter rack, it must first be configured specifically for the trans-
mitter.