Chapter 8
Service
2098.0188.72
- 8.32 -
E-1
9.3.1
Removing Differential Pressure Gage
Note
Prior to removal make sure which of the two differential pressure gages needs to be re-
placed.
1. Using a Torx screwdriver No. 20, remove the rear panel of the rack.
2. Remove the air connector (plastic tube).
3. Disconnect the associated cable from the connector on 
X45
 of the power distribution
board. 
(Pins 1 and 2 for differential pressure gage 1, or pins 3 and 4 for differential pressure
gage 2.)
4. Cut off the cable ties to free the cable.
5. Undo the two screws on the bracket.
6. Remove the differential pressure gage.
7. Unscrew the round cover and remove the cable (6.3 mm connector).
Fig. 24
Removing the differential pressure gage
9.3.2
Installing Differential Pressure Gage
To install the unit in the transmitter, reverse the procedure used to remove it.
 Check whether the protective cap for the air nozzle on the left-hand differential pressure
gage has already been removed and if not, remove it (see figure).