Chapter 8
Service
2098.0188.72
- 8.33 -
E-1
Fig. 25
Differential pressure gage without protective cap
Note
After installation the differential pressure gage must be set to the switching point of 200 Pa
again. 
1. Remove the transparent top cover.
In the middle is an adjuster with a scale.
2. Use a screwdriver to turn the adjuster until the arrow points to the value 200.
9.4
Replacing Temperature Sensors
The transmitter rack contains two temperatur sensors which measure the intake and outlet
air temperatures. They are located on the intake and outlet lines on the rack.
9.4.1
Removing Temperature Sensor
Note
Prior to removal make sure which of the two temperature sensors needs to be replaced.
1. Using a Torx screwdriver No. 20, remove the rear panel of the rack.
2. Unplug the connector of the temperature sensor concerned.
WARNING!
Always make sure that the power supply is disconnected before commencing any service 
work on the transmitter rack. This will prevent injury due to electric shock and avoid dam-
age to the instruments.