Brother LK3-B438E MKII Benutzeranleitung

Seite von 262
149
ZE-8570,8580
12. REPLACING PARTS
12. ERSETZEN VON TEILEN
12. REMPLACEMENT DES PIECES
12. CAMBIO DE PARTES
■ Removal
1. Remove the two screws 
q, and then remove the bed
plate 
w.
2. Loosen the set screw 
r of the set collar e to release
the cutting pressure of the edge knife 
t.
3. Remove the screw 
y, and then remove the needle
plate cover 
u.
4. Use the accessory Z-shape screwdriver to remove the
screw 
i, and then remove the edge knife t.
5. Remove the two screws 
o, and then remove the fixed
edge knife 
!0.
■ Installation
NOTE:
Either side of the standard fixed edge knife can be
used.
1. Place the fixed edge knife 
!0 into the groove in the
needle plate 
!1 so that dimensions A and B in the il-
lustration are equal to each other, and then secure it
by tightening the two screws 
o.
2. Use the Z-shaped screwdriver to tighten the screw 
i
to install the edge knife 
t so that it gap between it
and the fixed edge knife 
!0 is 0.03  to 0.05 mm.
* If the edge knife 
t cannot be installed at a slight
angle, or if it does not cut properly, install the edge
knife 
t to the edge knife bracket !2, and then loosen
the two screws 
!3 and tilt the edge knife bracket !2
so that the edge knife 
t is at a slight angle.
However, if the angle is too large, the blade will
reach the end of its useful life more quickly.
3. Adjust the cutting pressure of the edge knife 
t using
the set screw 
r of the set collar e. (Refer to page 170.)
4. Install the needle plate cover 
u with the screw y.
5. Install the bed plate 
w with the two screws q.
o
12-2. Edge knife
1539M
1536M
1538M
q
w
e
r
y
u
i
o
!1
!0
o
o
!0
o
i
t
t
!2
0.03~0.05mm
!2
!3
1627M
!1
!0
Align centers of 
grooves 
!0 and !1.
<For optional fixed edge knife>