Adam Equipment Marine Radio CBC SERIES Benutzerhandbuch

Seite von 28
 
© Adam Equipment Company 2009 
12 
automatically. 
 
•  This  feature  is  turned  off  as  soon  as  the  number  of  items  added 
exceeds the count used as a sample. 
 
6.3.4 Check-counting 
 
•  Check-counting is a procedure to cause an alarm to sound when 
the  number  of  items  counted  on  the  scale  meets  or  exceeds  a 
number stored in the memory by using the 
[Pst] key. 
 
•  The  value  to  be  stored  is  entered  from  the  keyboard.  Enter  the 
numeric  value  to  be  stored  using  the  numeric  keys.  Then  press 
the 
[Pst] key to store the value. 
 
•  To  clear  the  value  from  the  memory  and  thereby  turn  off  the 
check-counting feature, enter the value "0" and press 
[Pst]. 
 
6.3.5 Manually Accumulated Totals 
 
•  The  values  (weight  and  count)  shown  on  the  display  can  be 
added to the values in the memory by pressing the 
[M+] key. The 
"
Weight"  display  will  show  the  total  weight,  the  "Count"  display 
will  show  the  total  accumulated  count  and  the  "
Unit  Weight
display shows the number of times, the items have been added to 
the  memory  for  accumulation.  The  values  will  be  displayed  for  2 
seconds before returning to normal. 
 
•  The  scale  must  return  to  zero  or  a  negative  number,  before 
another sample can be added to the memory.  
 
•  More products can then be added and the [M+] key to be pressed 
again. This can continue for up to 99 entries or until the capacity 
of the “
Weight” display is exceeded. 
 
•  To  observe  the  total  stored  value,  press  the  [MR]  key.  The  total 
will be displayed for 2 seconds. 
 
•  To  clear  the  memory-  first  press  [MR]  to  recall  the  totals  from 
memory and then press the 
[CE] key to clear all values from the 
memory.