Note 
Killed axes are not affected by the triggering of the abort. They do not 
get enabled (unlike the software abort command).  
 
 
Note 
There are no software configurable parameters to enable or disable the 
hardware Abort Input functionality. 
 
Wiring the Watchdog Output  
 
Watchdog Output, 
Normally Open  
 
Watchdog Output, 
Normally Closed 
1
2
3
4
5
24 VDC 
Power Supply
COM                      24VDC
Logic device
(safe shutdown)
COM        24VDC
 
 
1
2
3
4
5
24 VDC 
Power Supply
COM                      24VDC
Logic device
(safe shutdown)
COM        24VDC
 
 
Operation 
Mode 
Connection between pins 
#5 and #3 
Connection between pins 
#5 and #4 
Watchdog 
Not triggered 
(normal operation)  
Open 
Closed 
Triggered  
(Faulty operation) 
Closed 
Open