Trane Gas Unit Heaters Wartungshandbuch

Seite von 44
Maintenance
34
 GAND-SVX01B-EN
Installation Instructions for Field 
Replacement of Power Venter Motor
Important:
This replacement must be performed only 
by a qualified technician.
Note: All hardware (screws, nuts, washers) that will be 
removed from the unit will be reused for this motor 
replacement. DO NOT LOSE ANY OF THESE 
PARTS.
Tools and Parts Needed
Wire Stripper and Crimper; Slotted Head and #2 Phillips 
Head Screwdriver; 3/8-in. Wrench; 1/8-in. Allen Wrench 
(long handle); marker; (1) 1/4-in. push on terminal for Wire.
Notes:
Remove the cover from the Relay Junction Box (Item 1) 
by removing two screws (Item 2) top and bottom. 
Disconnect both wires from the motor lead ends. One 
is connected to terminal #4 on the venter relay, and the 
other is connected with a wire nut to a black wire.
Remove the sensing tube (Item 3) from the Pressure 
Switch/Mounting Bracket (Item 3) at motor end only. 
Separated Combustion Units: Remove both tubes at 
motor end only—note location.
Mark locations of the Relay Junction Box and Pressure 
Switch Mounting Brackets along with the Motor (Item 
10) mounts on the Mounting Adapter Plate (Item 4)—
using a marker.
Remove nut (Item 5) that secures the Motor Support 
Shipping Bracket (Item 6) to the Mounting Adapter 
Plate. Pull this bracket away from the Motor Mounting 
Adapter Plate.
Remove three phillips head screws (Item 7) on the 
Motor mounting Adapter Plate. Remove the Motor/
Blower Wheel/Adapter Plate assembly from the Power 
Venter Blower Housing (Item 8).
Remove the Blower Wheel (Item 9) from the motor 
shaft by removing the set screw (Item 14) using a 1/8-in. 
Allen Wrench.
Remove the three Motor Mounting Nuts (Item 5), 
Space Washers (Item 11), and Screws (Item 12). Do not 
lose these parts! Using caution—the motor will 
disengage from the Mounting Adapter Plate, along 
with the Relay Junction Box and Pressure Switch 
Mounting Brackets will also disengage.
Reverse order to install the new Power Venter Motor.
TEST FIRE THE UNIT FOR A FEW CYCLES, MAKING 
SURE THAT THE UNIT IS OPERATING 
SATISFACTORILY.
Figure 23. Identification of parts
Ref. No.
Description
 1
Relay Junction Box/Mounting 
Bracket Assembly
 2
#8 Drill Screws (2 required)
 3
Pressure/Mounting Bracket 
Assembly 
 4
Mounting Plate Adapter
 5
Keps Nut w/External Tooth 
Lockwasher (4 required)
 6
Motor Support Shipping Bracket
 7
Phillips Head Screws (3 required)
 8
Power Venter Blower Housing
 
9
Blower  Wheel
10
Motor
11
Space Washers (3 required)
12
Machine Screw (3 required)
13
Sensing Tube
14
Set Screw