KatalogInhaltsverzeichnisIntroduction2Features Highlights4Features and Benefits5Application Considerations7General7Venting Unit Heaters12Selection Procedure16Indoor Gas Heating Units18Horizontal Blower Assembly19Model Number Descriptions18General Data20Service Clearances20Heat Throw Data20Performance Data24Controls30Gas Controls30Sequence of Operations33Single-Stage Control33Two-Stage Control34Electronic Modulating Control (with duct thermostat)35Electronic Modulating Control (with room thermostat)37High-Efficiency Units39Separated Combustion Units43Electrical Data45Dimensions and Weights46Mechanical Specifications58Tubular Heat Exchanger Indoor Gas Unit (model GT)58High Efficiency Propeller (model GH) and Centrifugal Fan Gas Unit Heaters (model GB)59Separated Combustion Centrifugal (model GK) and Propeller Fan Gas Unit Heaters (model GA)61High Efficiency Indoor Gas Duct Furnaces (model GL)63Separated Combustion Duct Furnaces (model GM)65Horizontal Blower Assembly (model HBAC)67Größe: 4,41 MBSeiten: 69Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisWarnings, Cautions and Notices2Introduction4Model Number Descriptions6Indoor Gas Heating Units6General Information7Description7General Safety Information7Identification of Parts8Unit Dimensions and Weights10Installation: Mechanical12Air Distribution12Clearances13Nozzle Assembly14Installation: Piping16Gas Supply Piping16Pipe Sizing16Pipe Installation17Installation: Venting18Venting for Power Vented (Category III) Unit Heaters18Installation: Electrical24Electrical Connections24Thermostat Wiring and Location24Start-Up26Operation27Power Vented Propeller Units with Intermittent (Spark) Pilot Ignition27Gas Equipment Start-Up32Maintenance33Periodic Service33Installation Instructions for Field Replacement of Power Venter Motor36How to Order Replacement Parts37Diagnostics38Troubleshooting38Wiring Diagrams42Größe: 5,06 MBSeiten: 43Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisWarnings, Cautions and Notices2Introduction4Model Number Descriptions6Indoor Gas Heating Units6General Information7Description7General Safety Information7Identification of Parts8Unit Dimensions and Weights10Installation: Mechanical12Air Distribution12Clearances13Nozzle Assembly14Installation: Piping16Gas Supply Piping16Pipe Sizing16Pipe Installation17Installation: Venting18Combustion Air Venting and Piping18Exhaust Venting19Installation: Concentric Vent Terminal21Horizontal Termination21Vertical Termination22Installation: Electrical24Electrical Connections24Thermostat Wiring and Location24Start-Up26Operation26Gas Equipment Start-Up30Maintenance31Periodic Service31Installation Instructions for Field Replacement of Power Venter Motor34How to Order Replacement Parts35Diagnostics36Troubleshooting36Wiring Diagrams40Größe: 5,46 MBSeiten: 44Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisDescription3Model Number Description4General Safety Information5Installation7Gas Piping10Pipe Installation11Blower Set Up and Adjustment12Motor and Pulley13Electrical Connections14Venting19(Category I)19(Category III)20Tubular Propeller Troubleshooting Guide23Primary Shutter Adjustment25Gas Input Rate25LED Indicator Assistance26Maintenance30Limited Warranty31Identification of Parts Propeller Unit Heaters32Gas Equipment Start-Up34Größe: 1,7 MBSeiten: 35Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisIntroduction2Warnings, Cautions, and Notices2General Safety Information3Copyright4Model Number Description6General Information7Dimensional Data and Weights8Performance Data9Installation10Locating Units10Clearances10Accessibility Clearance10Atmospheric Considerations10Aircraft Hangars10Public Garages10Ductwork11Air Flow11Combustion Inlet Air Ventilation11Bypass11Suspension12Conversion of access side12Gas Pipe Sizing13Pipe Sizing13Pipe Installation14Venting16Venting for Power Vented Duct Furnaces (Category III)16Vertically Vented Duct Furnaces (Category III)17Horizontally Vented Duct Furnaces (Category III)17Combustion Air20Exhaust Venting21Electrical Connections25Thermostat Wiring and Location25Operation27Tubular Duct Furnace Direct Spark Ignition27Explanation of Controls27Start-Up27Shut Down27Gas Input Rate28Tubular Duct Furnace—High Altitude Deration29Gas Equipment Start-Up30Maintenance31Periodic Service31Identification of Parts Tubular Duct Furnace32How To Order Replacement Parts33Troubleshooting34Warranty38Größe: 3,65 MBSeiten: 39Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisWarnings, Cautions and Notices2Introduction4Model Number Descriptions6Indoor Gas Heating Units6Horizontal Blower Assembly6General Information7Description7General Safety Information7Identification of Parts8Unit Dimensions and Weights10Installation: Mechanical12Clearances12Air Flow13Suspension14Nozzle Assembly14Installation: Piping16Gas Piping16Pipe Sizing16Pipe Installation17Installation: Venting18Combustion Air Venting and Piping18Exhaust Venting19Installation: Concentric Vent Terminal21Horizontal Termination21Vertical Termination22Installation: Electrical24Electrical Connections24Thermostat Wiring and Location24Start-Up26Operation26Gas Equipment Start-Up30Maintenance31Periodic Service31Installation Instructions for Field Replacement of Power Venter Motor33How to Order Replacement Parts34Diagnostics35Troubleshooting35Wiring Diagrams39Größe: 5,09 MBSeiten: 41Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisWarnings, Cautions and Notices2Introduction4Model Number Descriptions6Indoor Gas Heating Units6Horizontal Blower Assembly6General Information7Description7General Safety Information7Identification of Parts8Unit Dimensions and Weights9Installation: Mechanical11Clearances12Air Flow13Combustion Inlet Air Ventilation13Suspension13Nozzle Assembly14Installation: Piping16Gas Piping16Pipe Sizing16Pipe Installation17Installation: Venting18Venting for Power Vented (Category III) Duct Furnaces19Installation: Electrical25Electrical Connections25Thermostat Wiring and Location25Start-Up27Operation27Power Vented Duct Furnaces with Intermittent (Spark) Pilot Ignition27Gas Equipment Start-Up32Maintenance33Periodic Service33Installation Instructions for Field Replacement of Power Venter Motor36How to Order Replacement Parts37Diagnostics38Troubleshooting38Wiring Diagrams42Größe: 5,04 MBSeiten: 43Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisWarnings, Cautions and Notices2Introduction4Model Number Descriptions6Indoor Gas Heating Units6General Information7Description7General Safety Information7Identification of Parts8Unit Dimensions and Weights10Installation: Mechanical12Air Distribution12Clearances13Nozzle Assembly14Installation: Piping16Gas Supply Piping16Pipe Sizing16Pipe Installation17Installation: Venting18Combustion Air Venting and Piping18Exhaust Venting19Installation: Concentric Vent Terminal21Horizontal Termination21Vertical Termination22Installation: Electrical24Electrical Connections24Thermostat Wiring and Location24Start-Up26Operation27Gas Equipment Start-Up31Maintenance32Periodic Service32Installation Instructions for Field Replacement of Power Venter Motor35How to Order Replacement Parts36Diagnostics37Troubleshooting37Wiring Diagrams41Größe: 5,44 MBSeiten: 43Language: EnglishHandbuch öffnen
WartungshandbuchInhaltsverzeichnisWarnings, Cautions and Notices2Introduction4Model Number Descriptions6Indoor Gas Heating Units6General Information7Description7General Safety Information7Identification of Parts8Unit Dimensions and Weights12Installation: Mechanical16Air Distribution16Clearances17Nozzle Assembly19Installation: Piping21Gas Supply Piping21Pipe Sizing21Pipe Installation22Installation: Venting23Standard Combustion25All Unit Sizes: Vertically Vented Unit Heaters (Category I)25All Unit Sizes: Horizontally Vented Unit Heaters (Category III)26Unit Sizes 30–120 Only: Vertically Vented Unit Heaters (Category III)28Separated Combustion32Unit Sizes 30–120 Only: Category III32Installation: Electrical37Electrical Connections37Thermostat Wiring and Location37Start-Up39All Unit Sizes: Operation39Power Vented Propeller Units—Direct Spark Ignition39Gas Equipment Start-Up43Maintenance44Periodic Service44How to Order Replacement Parts45Diagnostics46Troubleshooting46Wiring Diagrams50Größe: 8,68 MBSeiten: 53Language: EnglishHandbuch öffnen