Ventilation appliances
A T 400 101
Stainless steel
Width 106 cm
Air extraction/recirculation
Width 106 cm
Air extraction/recirculation
A T 400 131
Stainless steel
Width 136 cm
Air extraction/recirculation
Width 136 cm
Air extraction/recirculation
Installation accessories
A A 010 410
A A 010 410
Air exhaust grille recirculation mode
Stainless steel coloured, 90 cm,
including installation fittings, height
adjustable.
Stainless steel coloured, 90 cm,
including installation fittings, height
adjustable.
A A 409 400
Furniture support 86 cm for table
ventilation 106/90 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
ventilation 106/90 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
A A 409 430
Furniture support 116 cm for table
ventilation 136/120 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
ventilation 136/120 cm
Recommended as bearer for the
worktop, instead of a cabinet frame.
A A 409 900
Telescopic extension 110 mm for
AT 400 101
AT 400 101
A A 409 930
Telescopic extension 110 mm for
AT 400 131
AT 400 131
Z B 020 090
Ventilation grille stainless steel
Extension piece for 30 mm, necessary
for height adjustment.
Order 1 for height adjustment of
31-60 mm.
Order 2 for height adjustment of
61-70 mm.
Extension piece for 30 mm, necessary
for height adjustment.
Order 1 for height adjustment of
31-60 mm.
Order 2 for height adjustment of
61-70 mm.
Special accessories
A A 400 010
A A 400 010
Beech cutting board, 28 cm deep, fits
the workspace on top of the AT 400
the workspace on top of the AT 400
A A 400 200
Glass cover, matt-finished, 106 cm,
thickness 6 mm, with spacer
thickness 6 mm, with spacer
A A 400 230
Glass cover, matt-finished, NO_FEA-
TURE, thickness 6 mm, with spacer
TURE, thickness 6 mm, with spacer
A A 409 101
Activated charcoal air filter incl. 2 extra
fine grease filters for AT 400 101
fine grease filters for AT 400 101
A A 409 131
Activated charcoal air filter incl. 2 extra
fine grease filters for AT 400 131
fine grease filters for AT 400 131
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Table ventilation
A T 400
– An eye-catcher for an island
solution or with CI 490 for the
60 cm deep worktop
60 cm deep worktop
– Highly effective air recirculation
technology, 750 m³/h air output at
source
source
– Additional workspace
– Minimal planning and easy
installation for air recirculation
Output
Performance output level 3/Intensive:
Air output according to DIN EN 61591.
Sound power and sound pressure
depending on built-in situation.
Air output according to DIN EN 61591.
Sound power and sound pressure
depending on built-in situation.
Appliance width 106/136 cm
Air extraction:
660 / 750 m³/h.
Air recirculation:
680 / 750 m³/h.
Air extraction:
660 / 750 m³/h.
Air recirculation:
680 / 750 m³/h.
Features
3 electronically controlled output
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Centrifugal grease filter and drip trays,
dishwasher-safe.
Fluorescent tube 30/36 W .
Order activated charcoal filter mat
separately.
levels.
Intensive mode.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Centrifugal grease filter and drip trays,
dishwasher-safe.
Fluorescent tube 30/36 W .
Order activated charcoal filter mat
separately.
Planning notes
AT 400 101 for operation with 2 Vario
400 series cooktops or cooktops up to
92 cm wide.
AT 400 131 for operation with 3 Vario
400 series cooktops or cooktops up to
122 cm wide.
For operation with 3 Vario 200 series
cooktops, 2 Vario 400 Series cooktops
or a cooktop configuration of up to
92 cm wide.
Max. output of glass ceramic cooktops
12 kW.
In combination with the cooktop
CI 490, installation in 60 cm deep
worktops is possible.
Operation in combination with gas
cooktops is not permitted.
The remaining surface of the worktop
(min. 50 mm) between the cut-outs
must be reinforced with a support. It is
recommended to use furniture support
AA 409 400/430.
Intermediate shelves in the lower
cabinet must be removable.
Hinges on swing doors may have to be
repositioned.
The connecting cables of the cooking
appliances are laid through the middle
of the air duct to the rear.
Water inlet and outlet pipes must not
be laid through the air duct.
When operating Vario cooktops, the
appliance cover needs to be removed.
Ovens that do not exceed the maximum
allowed cabinet temperature can be
combined with the table ventilation if
built-in situation permits.
The table ventilation cover must remain
removable to permit changing of the
lamp.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4301,
ground and brushed IIIC.
400 series cooktops or cooktops up to
92 cm wide.
AT 400 131 for operation with 3 Vario
400 series cooktops or cooktops up to
122 cm wide.
For operation with 3 Vario 200 series
cooktops, 2 Vario 400 Series cooktops
or a cooktop configuration of up to
92 cm wide.
Max. output of glass ceramic cooktops
12 kW.
In combination with the cooktop
CI 490, installation in 60 cm deep
worktops is possible.
Operation in combination with gas
cooktops is not permitted.
The remaining surface of the worktop
(min. 50 mm) between the cut-outs
must be reinforced with a support. It is
recommended to use furniture support
AA 409 400/430.
Intermediate shelves in the lower
cabinet must be removable.
Hinges on swing doors may have to be
repositioned.
The connecting cables of the cooking
appliances are laid through the middle
of the air duct to the rear.
Water inlet and outlet pipes must not
be laid through the air duct.
When operating Vario cooktops, the
appliance cover needs to be removed.
Ovens that do not exceed the maximum
allowed cabinet temperature can be
combined with the table ventilation if
built-in situation permits.
The table ventilation cover must remain
removable to permit changing of the
lamp.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4301,
ground and brushed IIIC.
For air recirculation:
Order activated charcoal filter mat
separately.
The opening in the lower cabinet shelf
may be increased as long as a
minimum cross-section of 1,800 cm² is
maintained.
The exhaust outlet in the plinth should
be as large as possible to minimise
draughts.
The location of the exhaust outlet in the
plinth is consumer-defined. Minimum
cross-section 720 cm².
To avoid smoke when frying/grilling
refer to the manuals of VR/VP.
Order activated charcoal filter mat
separately.
The opening in the lower cabinet shelf
may be increased as long as a
minimum cross-section of 1,800 cm² is
maintained.
The exhaust outlet in the plinth should
be as large as possible to minimise
draughts.
The location of the exhaust outlet in the
plinth is consumer-defined. Minimum
cross-section 720 cm².
To avoid smoke when frying/grilling
refer to the manuals of VR/VP.
For air extraction:
Attachment of exhaust pipe directly in
the blower housing using flexible duct
DN 150 or 90° elbow pipe AD 752 030.
Break-out openings for cylindrical pipe
AD 752 010 in the blower housing.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Attachment of exhaust pipe directly in
the blower housing using flexible duct
DN 150 or 90° elbow pipe AD 752 030.
Break-out openings for cylindrical pipe
AD 752 010 in the blower housing.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Connection
Total connected load 310/316 W .
Connecting cable 2.0 m with plug (from
middle of appliance).
Connecting cable 2.0 m with plug (from
middle of appliance).