Model 3088RC Configuration Slot X page MIB variables description
201
Model 1001MC Operations Guide 
9 • Model 3088RC management
Protected (disableGlobalConfig)
You can protect individual rack cards from being globally configured by setting the pop-up menu from nor-
mal(0)
 to protected(1). After you have set the protection option, if you are finished making changes to the cur-
rent rack card, click on the 
Submit
 button (located at the right side of the rack card’s row in the table) to save 
the changes.
Note
Setting the protection to normal(0) will enable the rack card to receive 
new configurations through the global configuration command. 
Note
After submitting the protection setting, you must click on the 
Record 
Current Configuration
 button located on the 
HOME
 page to store 
the configuration changes into memory (see 
for more information).
Local Circuit ID (localCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string 
can be changed within the 
Configure Cards
 page or from the 
Slot Configuration
 page. After clicking the 
Sub-
mit Query
 button to input the string to the management system, you are required to select the 
Record Current 
Configuration
 button on the Model 1001MC button on the Model 1001MC 
HOME
 page. This will store the 
information into flash making it available after a re-boot or power cycle.
Remote Circuit ID (remoteCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC. This string 
can be changed from the 
Configure Cards
 web page or from the 
Slot Configuration
 page. 
Submit button
Click the 
Submit 
button to input the changes to the management system. After clicking the 
Submit 
button, you 
are required to select the 
Record Current Configuration
 button on the Model 1001MC button on the Model 
1001MC 
HOME
 page. This will store the information into flash making it available after a re-boot or power cycle.
Note
After submitting the remote circuit ID information, you must click 
on the 
Record Current Configuration
 button located on the 
HOME
 
page to store the configuration changes into memory (see 
on page 228 for more information).
Model 3088RC Configuration Slot X page MIB variables description
This section describes the MIB variables that are available on the Model 3088RC Configuration Slot X page. 
(See 
 on page 193). Starting from the 
HOME
 page, click on the following links: Home (menu) > Config-
ure Cards (menu) > View Rack [rack number] > model3088RC-xxx(x) (in the Local Model Code column).
Model 3088RC Configuration Slot (nmsSlotID)
Displays the address of the NetLink E1-G.SHDSL NTU. The address is defined by the DIP-switch setting of 
S3 and S4 on the rack card.