Patton electronic 1001MC Benutzerhandbuch

Seite von 288
Model 3088RC Configuration Slot X page MIB variables description
202
Model 1001MC Operations Guide 
9 • Model 3088RC management
Line Status (lineStatus)
Displays the status of the line. There are three possible values that can be displayed:
linedown(1)
dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
testMode(3)
Alarm counters
For the four alarm counters, you may choose to do numerous actions upon detecting errors: nothing, incre-
ment the counter upon each occurrences of the error, send an SNMP trap, or send a Syslog message. The 
choice is determined by configuring the 
Line Down Indicator
 on the 
Slot Configuration Page
. The following 
table clarifies what the parameter will do.
LOS (losAlarm)
Displays the number of times Loss of Sync on the E1 line is detected. It is incremented when synchronization 
to the E1 stream is lost. This number is accumulating in the 1001MC.
Note
Alarm counters severity level is controlled by the “Line Down Indica-
tion” level. The following options are available:
none—Only Syslog message will be sent
warning—Syslog message will be sent beginning with “box\box.c: 
Warning:” and web page warning counter will be incremented
error—Syslog message will be sent beginning with “box\box.c: 
Error:”, the web page error counter will be incremented, and an 
SNMP trap message will be sent
Send a Syslog message
Increment the Alarm Counter 
on the web page
Send an SNMP trap
None
Warning
Error