Slot Configuration page MIB variables description
209
Model 1001MC Operations Guide 
9 • Model 3088RC management
Software Test Mode (testModeSet3088RC)
This is used to invoke test modes through the NMS. Available options are:
lal(4)—Local loopback test
rdl(7)—Remote loopback test from V54 
RDL Response(v54Loop)
The following options are available:
enabled(1)—The unit will respond to a V.54 loop up command
disabled(0)—The unit will ignore a V.54 loop up command
FP Switches (frntSwitch)
This selects if the front panel toggle switches used for loopbacks and pattern generators are:
enabled(1)
disabled(0).
Slot Configuration page MIB variables description
This section describes the MIB variables that are available on the 
Slot Configuration 
page. From the 
Modem Infor-
mation 
page, the address column creates a list of hyperlinks to the 
Slot Configuration
 page associated with the spec-
ified address. The 
Slot Configuration
 page can be used to set slot-specific information related to the system and 
how the system treats the slot in the case of errors and warning. Starting from the 
HOME
 page, click on the follow-
ing links: Home (menu) > Configure Cards (menu) > View Rack [rack number] > X (in the Card Address column).
Card Address (nmsSlotID)
Displays the address of the card.
Local Model Code (localModelCode)
Displays the model code of the NetLink modem installed at the specified address.
View Rack X hyperlink
Click on the View Rack X link to display the 
Modem Information Rack X
 on page 239 for more information).
Card Identification Information
Local User Id (localUserID)
User supplied string that defines the NetLink NTU installed in the rack. The string is stored in non-volatile 
flash within the NetLink NTU and is useful for hardware identification. If the address of the modem is 
changed, the User ID will move to the new slot. The string can be up to 10 bytes long and can be changed or 
reset within this page.