Patton electronic 1001MC Benutzerhandbuch

Seite von 288
System Level Information
238
Model 1001MC Operations Guide 
10 • HTTP/HTML web page reference
Apply Test Mode
If you are going to be running in test mode, select one of the following test patterns from the pop-up menu, 
then click the 
Apply Test Mode
 button.
off(0)
five11(2)—511 is the pattern that is used when the pattern generator and detector are turned on
five11er(3)—511 with errors is the pattern that is used when the pattern generator and detector are turned on
lal(4)—Local loopback
lalWith511(5)—Local loopback with pattern generator set to output 511 pattern
lalWith511er(6)—Local loopback with pattern generator set to output 511 pattern with errors
rdl(7)—Remote digital loopback
rdlWith511(8)—Remote digital loopback with pattern generator set to output 511 pattern
rdlWith511er(9)—Remote digital loopback with pattern generator set to output 511 pattern with errors
Rack Protection Mode
If you want to protect all Model 1095RC rack cards installed in the current rack from being globally config-
ured, select protected(1) from the pop-up menu, then click the 
Apply Protection 
button. For more information 
about the system configuration feature, refer to section 
Note
Setting the Rack Protection Mode to normal(0) will enable the rack to 
receive new configurations through the global configuration command. 
Clear Rack Alarms (clearAlarms)
Click on this button to clear alarms reported by the system for this rack. 
Note
The System Log will still display the errors after the 
Clear Rack 
Alarms