Smeg ALFA201XE Benutzerhandbuch

Seite von 17
 
 
Instructions for the Installer
 
 
24
 
2.2  Safety thermostat 
The oven is fitted with a safety device tripped in case of a serious 
malfunction. To reset the safety device, call the after-sales service. 
 
 
 
 
The manufacturer declines all responsibility for injury or damage 
caused by failure to comply with the above regulations or deriving from 
tampering with even just one part of the appliance. 
 
 
2.3  Levelling 
 
Level the oven by means of its four adjustable feet. To make the 
adjustment, undo the lock-nut and unscrew the foot. The adjuster screw 
travel is 10 mm. 
 
2.4  Connection to the water supply 
Connect the water inlet connection 
on the rear to a water supply outlet 
having ¾ gas threaded connection, 
taking care to screw tightly to the 
hose.  
If the water supply pipe is new or 
has been unused for a long time, 
before making the connection turn 
the water on and allow it to flow out 
to ensure that it is clear and free 
from impurities. Otherwise, the 
water inlet may become fouled, 
damaging the oven. 
The oven must be supplied with 
water at a pressure between min. 
50 kPa and max. 500 kPa.
 
aaaaaaaaaaa
aaaaaaaaaaa
 
 
 
2.5  Steam vent pipe (Mod. Alfa 200XE) 
The top of the oven is fitted with a pipe 
which vents the steam produced during 
cooking. This pipe must be left free of all 
obstructions.  Take care not to obstruct 
it.